Evidence map›Paper›PMID 31485963›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2021

Body weight-dependent Rubidium-82 activity results in constant image quality in myocardial perfusion imaging with PET.

J D van Dijk, M Dotinga, P L Jager, C H Slump, J P Ottervanger, M Mouden, J A van Dalen

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Exponential dosing to standardize myocardial perfusion image quality with rubidium-82 PET.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  3. The prevalence of image degradation due to motion in rest-stress rubidium-82 imaging on a SiPM PET-CT system.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  4. Activity regimes for 82Rb cardiac PET: Effects on absolute MBF and MPI.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
  5. Effects of two patient-specific dosing protocols on measurement of myocardial blood flow with 3DEuropean journal of nuclear medicine and molecular imaging · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

J D van DijkDepartment of Nuclear Medicine, Isala, PO Box 10400, 8000 GK, Zwolle, The Netherlands. jorisvdijk@gmail.com.ORCID http://orcid.org/0000-0001-7514-789X
M DotingaDepartment of Nuclear Medicine, Isala, PO Box 10400, 8000 GK, Zwolle, The Netherlands.
P L JagerDepartment of Nuclear Medicine, Isala, PO Box 10400, 8000 GK, Zwolle, The Netherlands.
C H SlumpMIRA: Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands.
J P OttervangerDepartment of Cardiology, Isala, Zwolle, The Netherlands.
M MoudenDepartment of Cardiology, Isala, Zwolle, The Netherlands.
J A van DalenDepartment of Medical Physics, Isala, Zwolle, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundClinical practice shows degrading image quality in heavier patients who undergo myocardial perfusion imaging (MPI) with Rubidium-82 (Rb-82) PET when using a fixed tracer activity. Our aim was to derive and validate a patient-specific activity protocol resulting in a constant image quality in PET MPI.

methodsWe included 251 patients who underwent rest MPI with Rb-82 PET (Discovery 670, GE Healthcare). 132 patients were included retrospectively and were scanned using a fixed activity of 740 MBq. The total number of measured prompts was normalized to activity and correlated to body weight, mass per body length and body mass index to find the best predicting parameter. Next, a patient-specific activity was derived and subsequently validated in 119 additional patients. Image quality was scored by three experts on a four-point scale.

resultsBoth image quality and prompts decreased in heavier patients when using a fixed activity (p < .005). Body weight was used to derive a new activity formula: Activity = 8.3 MBq/kg. When applying this formula, both measured prompts and scored image quality became independent of body weight (p > .60).

conclusionAdministrating a Rb-82 activity that linearly depends on body weight resulted in a constant image quality across all patients and is recommended.

Indexed as

Body WeightMyocardial Perfusion ImagingPositron-Emission TomographyAgedBody Mass IndexClinical ProtocolsCoronary Artery DiseaseFemaleHumansMaleMiddle AgedReproducibility of ResultsRetrospective StudiesRubidium RadioisotopesRubidium-82Rubidium Radioisotopesmyocardial perfusion imagingpatient doseRadiation dose reductionrubidium-82tracer activity

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.