ArticleThe AAPS journal2019
Fit-for-Purpose Quality Control System in Continuous Bioanalysis During Long-Term Pediatric Studies.
Article in The AAPS journal, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
- Erratum issued
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Pharmacokinetic studies are key to evidence-based pharmacotherapy. The reliability of pharmacokinetic parameters is closely related to the quality of bioanalytical data. Bioanalytical method validation is fully described by regulatory guidelines; however, it is conducted just once. To ensure reliability and comparability of clinical data, appropriate quality control systems must be enforced to monitor post-validation bioanalytical runs. While single bioanalytical run evaluation is described in international guidelines, somehow, the long-term reproducibility of the bioanalytical method is unattended; it becomes pivotal with the involvement of pediatric population. Therefore, a customized quality control system was developed that addresses regulatory requirements and encompasses the specific demands of pediatric research. It consisted of continuous multi-parameter assessment, including calibration curves, quality control samples, incurred sample reanalysis, and internal standard data. The recommendations provided by the guidelines were combined with the additional Westgard rules, statistical evaluation, and graphical observations. The applicability of the developed quality control system was investigated by using data from three pediatric clinical trials, where the system was able to identify 16% of all analytical runs as invalid. Using a pooled standard deviation provided a better estimate of long-term reproducibility by calculating the %CV, which ranged from 3.6 to 10.3% at all quality control levels. Irrespective of the difficulties encountered owing to vulnerable pediatric populations, the incurred sample reanalysis fulfilled the regulatory requirement of at least 67%. This quality control approach ensured reliable and comparable results over a whole 31-month duration in relation to pediatric studies.
Indexed as
Identifiers
31485787What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.