Evidence map›Paper›PMID 31485307›Full record

ArticleInterface focus2019

On the defect tolerance of fetal membranes.

Kevin Bircher, Alexander E Ehret, Deborah Spiess, Martin Ehrbar, Ana Paula Simões-Wüst, Nicole Ochsenbein-Kölble, Roland Zimmermann, Edoardo Mazza

Abstract read
In one paragraph

Article in Interface focus, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. A Review on Damage and Rupture Modelling for Soft Tissues.Bioengineering (Basel, Switzerland) · 2022
    Review
  10. Article
  11. Inflammatory Amplification: A Central Tenet of Uterine Transition for Labor.Frontiers in cellular and infection microbiology · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kevin BircherETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland.ORCID 0000-0003-4662-2000
Alexander E EhretETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland.ORCID 0000-0002-8740-8900
Deborah SpiessDepartment of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland.
Martin EhrbarDepartment of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland.
Ana Paula Simões-WüstDepartment of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland.
Nicole Ochsenbein-KölbleDepartment of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland.
Roland ZimmermannDepartment of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland.
Edoardo MazzaETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A series of mechanical experiments were performed to quantify the strength and fracture toughness of human amnion and chorion. The experiments were complemented with computational investigations using a 'hybrid' model that includes an explicit representation of the collagen fibre network of amnion. Despite its much smaller thickness, amnion is shown to be stiffer, stronger and tougher than chorion, and thus to determine the mechanical response of fetal membranes, with respect to both, deformation and fracture behaviour. Data from uniaxial tension and fracture tests were used to inform and validate the computational model, which was then applied to rationalize measurements of the tear resistance of tissue samples containing crack-like defects. Experiments and computations show that the strength of amnion is not significantly reduced by defects smaller than 1 mm, but the crack size induced by perforations for amniocentesis and fetal membrane suturing during fetal surgery might be larger than this value. In line with previous experimental observations, the computational model predicts a very narrow near field at the crack tip of amnion, due to localized fibre alignment and collagen compaction. This mechanism shields the tissue from the defect and strongly reduces the interaction of multiple adjacent cracks. These findings were confirmed through corresponding experiments, showing that no interaction is expected for multiple sutures for an inter-suture distance larger than 1 mm and 3 mm for amnion and chorion, respectively. The experimental procedures and numerical models applied in the present study might be used to optimize needle and/or staple dimensions and inter-suture distance, and thus to reduce the risk of iatrogenic preterm premature rupture of the membranes from amniocentesis, fetoscopic and open prenatal surgery.

Indexed as

computational modellingdefect toleranceexperimental mechanicsfetal membranefracture mechanicsstructural mechanics

Identifiers

PMID31485307
PMCPMC6710661

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.