Evidence map›Paper›PMID 31483821›Full record

ArticlePloS one2019

A novel lumen-apposing metal stent with an anti-reflux valve for endoscopic ultrasound-guided drainage of pseudocysts and walled-off necrosis: A pilot study.

In Rae Cho, Moon Jae Chung, Jung Hyun Jo, Hee Seung Lee, Jeong Youp Park, Seungmin Bang, Seung Woo Park, Si Young Song

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Time to think prime times for treatment of necrotizing pancreatitis: Pendulum conundrum.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2023
    Review
  2. Article
  3. Review
  4. Advancements in the endoscopic treatment of pancreatic fluid collections.Chronic diseases and translational medicine · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

In Rae ChoDepartment of Internal Medicine, Catholic Kwandong University College of Medicine, Incheon, Korea.
Moon Jae ChungDepartment of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0002-5920-8549
Jung Hyun JoDepartment of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.
Hee Seung LeeDepartment of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.
Jeong Youp ParkDepartment of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.
Seungmin BangDepartment of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.
Seung Woo ParkDepartment of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.
Si Young SongDepartment of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.
Yonsei University · KRCatholic Kwandong University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPancreatic pseudocysts (PC) and walled-off necrosis (WON) are common complications of severe pancreatitis. Endoscopic ultrasound (EUS)-guided drainage has replaced surgery as the standard treatment for PC/WON. We developed a novel lumen-apposing metal stent (LAMS) with an anti-reflux valve to prevent infectious complications caused by food reflux into the cyst cavity. This retrospective study investigated the efficacy and safety of EUS-guided drainage using this LAMS.

methodsWe investigated and compared the treatment outcomes and complications rates between EUS-guided drainage using a novel LAMS (n = 10) versus plastic stents (n = 18) from December 2013 to October 2016. Technical success was defined as successful stent placement without immediate complications. Clinical success was defined as resolution of the PC/WON and disappearance of symptoms.

resultsAmong 10 patients in LAMS group, 4 patients had complicated PC and 6 patients had WON. In the plastic stent group, 15 and 3 patients had PC and WON, respectively. The median fluid collection size before treatment was 82.5 (interquartile range [IQR], 60.75-118.25) mm and 92.0 (IQR, 75.75-130.25) mm in the LAMS and plastic stent groups, respectively. There were no statistically significant differences in technical success rates (90% vs. 94.4%; p = 0.999), clinical success rates (80% vs. 77.8%; p = 0.999), and complication rates (20% vs. 27.8%; p = 0.999) between the two groups.

conclusionsTreatment outcomes of EUS-guided drainage using a novel LAMS were feasible despite the significantly high proportion of WON. The LAMS allowed acceptable treatment outcomes for EUS-guided drainage.

Indexed as

EndoscopyMetalsStentsAdultDrainageFemaleGastroesophageal RefluxHumansMaleMiddle AgedMotionPancreatic PseudocystPilot ProjectsRetrospective StudiesTreatment OutcomeUltrasonographyMetals

Identifiers

PMID31483821
PMCPMC6726198
OpenAlexW2971639923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.