Evidence map›Paper›PMID 31475170›Full record

ArticleAnnals of translational medicine2019

Comparison of Roche Elecsys and Sysmex HISCL immunoassays for the screening of common blood-borne pathogens.

Wanzhou Xu, Yongqing Tong, Yan Li

Open access · diamondAbstract read
In one paragraph

Article in Annals of translational medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Performance Evaluation ofFrontiers in cellular and infection microbiology · 2021
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Wanzhou XuDepartment of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
Yongqing TongDepartment of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
Yan LiDepartment of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan 430060, China.
Renmin Hospital of Wuhan University · CNWuhan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe conducted a comprehensive comparison in the sensitivity, specificity, dilution sensitivity, and precision between two immunoassay systems, Roche Elecsys Cobas e 601 and Sysmex HISCL 5000, for the detection of hepatitis B virus surface antigen (HBsAg), antibody to hepatitis C virus (anti-HCV), treponemal antibodies (anti-TP), and human immunodeficiency virus (HIV).

methodsOne thousand unselected samples and 100 reserved weak reactive samples were tested by the two systems. Sensitivity and specificity were then calculated for each system. Seroconversion panels were used to assess the sensitivity in early stage detection. Dilution sensitivity was evaluated by dilution tests of several seroconversion panel samples. Evaluation of within-run and intermediate precision was conducted following EP-15A protocol.

resultsThe consistency rates of the two systems for the detection of four pathogens were all over 99% among unselected samples. Both Elecsys and HISCL were observed to have high sensitivity and specificity in unselected samples and weak reactive samples. Seroconversion panel tests showed that Elecsys could identify positive results earlier than HISCL in HBsAg (1 out of 4), anti-TP (1 out of 2) and HIV (1 out of 12) panels. The results of the anti-HCV panels were comparable. In dilution tests, Elecsys could detect lower concentrations than HISCL in two anti-HCV samples and one anti-TP sample. The two systems had similar performance in dilution tests of HBsAg and HIV samples. Both Elecsys and HISCL had qualified intra-assay and inter-assay precision.

conclusionsBoth Elecsys and HISCL have good performance in the screening of four common bloodborne pathogens. The two systems are comparable and considered adequate for clinical use.

Indexed as

Blood-borne pathogensdiagnostic performanceRoche Elecsysserological testSysmex HISCL

Identifiers

PMID31475170
PMCPMC6694263
OpenAlexW2951568240

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.