Evidence map›Paper›PMID 31473800›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2019

Automatic classification of dopamine transporter SPECT: deep convolutional neural networks can be trained to be robust with respect to variable image characteristics.

Markus Wenzel, Fausto Milletari, Julia Krüger, Catharina Lange, Michael Schenk, Ivayla Apostolova, Susanne Klutmann, Marcus Ehrenburg, Ralph Buchert

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Detection of parkinson's disease with neuroimaging modalities using machine learning and artificial intelligence: a systematic review.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2026
    Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Dopaminergic PET to SPECT domain adaptation: a cycle GAN translation approach.European journal of nuclear medicine and molecular imaging · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Differential Diagnosis of Parkinsonism Based on Deep Metabolic Imaging Indices.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2022
    Article
  16. Review
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Markus WenzelFraunhofer Institute for Medical Image Computing MEVIS, Bremen, Germany.
Fausto MilletariComputer Aided Medical Procedures & Augmented Reality, Technical University Munich, München, Germany.
Julia KrügerJung diagnostics, Hamburg, Germany.
Catharina LangeDepartment of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
Michael SchenkDepartment for Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
Ivayla ApostolovaDepartment for Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
Susanne KlutmannDepartment for Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
Marcus EhrenburgPinax Pharma, Bad Liebenwerda, Germany.
Ralph BuchertDepartment for Diagnostic and Interventional Radiology and Nuclear Medicine, University Hospital Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany. r.buchert@uke.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study investigated the potential of deep convolutional neural networks (CNN) for automatic classification of FP-CIT SPECT in multi-site or multi-camera settings with variable image characteristics.

methodsThe study included FP-CIT SPECT of 645 subjects from the Parkinson's Progression Marker Initiative (PPMI), 207 healthy controls, and 438 Parkinson's disease patients. SPECT images were smoothed with an isotropic 18-mm Gaussian kernel resulting in 3 different PPMI settings: (i) original (unsmoothed), (ii) smoothed, and (iii) mixed setting comprising all original and all smoothed images. A deep CNN with 2,872,642 parameters was trained, validated, and tested separately for each setting using 10 random splits with 60/20/20% allocation to training/validation/test sample. The putaminal specific binding ratio (SBR) was computed using a standard anatomical ROI predefined in MNI space (AAL atlas) or using the hottest voxels (HV) analysis. Both SBR measures were trained (ROC analysis, Youden criterion) using the same random splits as for the CNN. CNN and SBR trained in the mixed PPMI setting were also tested in an independent sample from clinical routine patient care (149 with non-neurodegenerative and 149 with neurodegenerative parkinsonian syndrome).

resultsBoth SBR measures performed worse in the mixed PPMI setting compared to the pure PPMI settings (e.g., AAL-SBR accuracy = 0.900 ± 0.029 in the mixed setting versus 0.957 ± 0.017 and 0.952 ± 0.015 in original and smoothed setting, both p < 0.01). In contrast, the CNN showed similar accuracy in all PPMI settings (0.967 ± 0.018, 0.972 ± 0.014, and 0.955 ± 0.009 in mixed, original, and smoothed setting). Similar results were obtained in the clinical sample. After training in the mixed PPMI setting, only the CNN provided acceptable performance in the clinical sample.

conclusionsThese findings provide proof of concept that a deep CNN can be trained to be robust with respect to variable site-, camera-, or scan-specific image characteristics without a large loss of diagnostic accuracy compared with mono-site/mono-camera settings. We hypothesize that a single CNN can be used to support the interpretation of FP-CIT SPECT at many different sites using different acquisition hardware and/or reconstruction software with only minor harmonization of acquisition and reconstruction protocols.

Indexed as

Deep LearningTomography, Emission-Computed, Single-PhotonAgedAutomationDopamine Plasma Membrane Transport ProteinsFemaleHumansImage Processing, Computer-AssistedMaleParkinson DiseaseDopamine Plasma Membrane Transport ProteinsConvolutional neural networkDeep learningDomain adaptionDopamine transporterFP-CITSPECT

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.