ArticleEuropean journal of nuclear medicine and molecular imaging2019
Automatic classification of dopamine transporter SPECT: deep convolutional neural networks can be trained to be robust with respect to variable image characteristics.
Article in European journal of nuclear medicine and molecular imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Detection of parkinson's disease with neuroimaging modalities using machine learning and artificial intelligence: a systematic review.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2026Pooled it
- Machine Learning for the Diagnosis of Parkinson's Disease: A Review of Literature.Frontiers in aging neuroscience · 2021Pooled it
- SPECT hybrid approach combining conventional and deep features for early detection of Parkinson's disease.Physical and engineering sciences in medicine · 2026Article
- Delayed convergence of iterative reconstruction in dopamine transporter SPECT with multiple-pinhole collimators.Zeitschrift fur medizinische Physik · 2026Article
- Allometry correction in semi-quantitative analysis of dopamine transporter SPECT.EJNMMI research · 2025Article
- Fully automatic categorical analysis of striatal subregions in dopamine transporter SPECT using a convolutional neural network.Annals of nuclear medicine · 2025Article
- Interpretation of basal nuclei in brain dopamine transporter scans using a deep convolutional neural network.Nuclear medicine communications · 2025Article
- Incorporating label uncertainty during the training of convolutional neural networks improves performance for the discrimination between certain and inconclusive cases in dopamine transporter SPECT.European journal of nuclear medicine and molecular imaging · 2025Article
- Dopaminergic PET to SPECT domain adaptation: a cycle GAN translation approach.European journal of nuclear medicine and molecular imaging · 2025Article
- No impact of attenuation and scatter correction on the interpretation of dopamine transporter SPECT in patients with clinically uncertain parkinsonian syndrome.European journal of nuclear medicine and molecular imaging · 2023Article
- Article
- Automatic segmentation of the thalamus using a massively trained 3D convolutional neural network: higher sensitivity for the detection of reduced thalamus volume by improved inter-scanner stability.European radiology · 2023Article
- Machine learning within the Parkinson's progression markers initiative: Review of the current state of affairs.Frontiers in aging neuroscience · 2023Review
- A Computerized Analysis with Machine Learning Techniques for the Diagnosis of Parkinson's Disease: Past Studies and Future Perspectives.Diagnostics (Basel, Switzerland) · 2022Review
- Differential Diagnosis of Parkinsonism Based on Deep Metabolic Imaging Indices.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2022Article
- Molecular Imaging in Parkinsonian Disorders-What's New and Hot?Brain sciences · 2022Review
- Real-World Testing of a Machine Learning-Derived Visual Scale for Tc99m TRODAT-1 for Diagnosing Lewy Body Disease: Comparison with a Traditional Approach Using Semiquantification.Journal of personalized medicine · 2022Article
- Imperative Role of Machine Learning Algorithm for Detection of Parkinson's Disease: Review, Challenges and Recommendations.Diagnostics (Basel, Switzerland) · 2022Review
- Multiple-pinhole collimators improve intra- and between-rater agreement and the certainty of the visual interpretation in dopamine transporter SPECT.EJNMMI research · 2022Article
- Decoding the dopamine transporter imaging for the differential diagnosis of parkinsonism using deep learning.European journal of nuclear medicine and molecular imaging · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study investigated the potential of deep convolutional neural networks (CNN) for automatic classification of FP-CIT SPECT in multi-site or multi-camera settings with variable image characteristics.
methodsThe study included FP-CIT SPECT of 645 subjects from the Parkinson's Progression Marker Initiative (PPMI), 207 healthy controls, and 438 Parkinson's disease patients. SPECT images were smoothed with an isotropic 18-mm Gaussian kernel resulting in 3 different PPMI settings: (i) original (unsmoothed), (ii) smoothed, and (iii) mixed setting comprising all original and all smoothed images. A deep CNN with 2,872,642 parameters was trained, validated, and tested separately for each setting using 10 random splits with 60/20/20% allocation to training/validation/test sample. The putaminal specific binding ratio (SBR) was computed using a standard anatomical ROI predefined in MNI space (AAL atlas) or using the hottest voxels (HV) analysis. Both SBR measures were trained (ROC analysis, Youden criterion) using the same random splits as for the CNN. CNN and SBR trained in the mixed PPMI setting were also tested in an independent sample from clinical routine patient care (149 with non-neurodegenerative and 149 with neurodegenerative parkinsonian syndrome).
resultsBoth SBR measures performed worse in the mixed PPMI setting compared to the pure PPMI settings (e.g., AAL-SBR accuracy = 0.900 ± 0.029 in the mixed setting versus 0.957 ± 0.017 and 0.952 ± 0.015 in original and smoothed setting, both p < 0.01). In contrast, the CNN showed similar accuracy in all PPMI settings (0.967 ± 0.018, 0.972 ± 0.014, and 0.955 ± 0.009 in mixed, original, and smoothed setting). Similar results were obtained in the clinical sample. After training in the mixed PPMI setting, only the CNN provided acceptable performance in the clinical sample.
conclusionsThese findings provide proof of concept that a deep CNN can be trained to be robust with respect to variable site-, camera-, or scan-specific image characteristics without a large loss of diagnostic accuracy compared with mono-site/mono-camera settings. We hypothesize that a single CNN can be used to support the interpretation of FP-CIT SPECT at many different sites using different acquisition hardware and/or reconstruction software with only minor harmonization of acquisition and reconstruction protocols.
Indexed as
Identifiers
31473800What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.