Trial reportJournal of applied clinical medical physics2019
Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.
Trial report in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 14 citations in OpenAlex.
- Implementing Remote Radiotherapy Planning to Increase Patient Flow at a Johannesburg Academic Hospital, South Africa: Protocol for a Prospective Feasibility Study.JMIR research protocols · 2025Article
- Tuning a secondary dose verification software for a CT-guided online adaptive delivery system.Journal of applied clinical medical physics · 2025Article
- Is it still necessary to perform measured based pre-treatment patient-specific QA for SRS HyperArc treatments?Journal of applied clinical medical physics · 2024Article
- Clinical experience on patient-specific quality assurance for CBCT-based online adaptive treatment plan.Journal of applied clinical medical physics · 2023Article
- Commissioning of and preliminary experience with a new fully integrated computed tomography linac.Journal of applied clinical medical physics · 2021Article
- Commissioning of a Versa HDJournal of applied clinical medical physics · 2021Article
- Boosting radiotherapy dose calculation accuracy with deep learning.Journal of applied clinical medical physics · 2020Article
- Evaluating Mobius3D Dose Calculation Accuracy for Small-Field Flattening- Filter-Free Photon Beams.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 6 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (PDD) curves, beam profiles, output factors, leaf transmission factors and dosimetric leaf gaps (DLGs) were acquired in accordance with the AAPM task group reports No. 45 and No. 106 and the vendor-supplied documents. The measured data were imported into Eclipse TPS to build a VersaHD beam model. The model was validated by creating treatment plans spanning over the full-spectrum of treatment sites and techniques used in our clinic. The quality assurance measurements were performed using MatriXX, ionization chamber, and radiochromic film. The DLG values were iteratively adjusted to optimize the agreement between planned and measured doses. Mobius, an independent LINAC logfile-based quality assurance tool, was also commissioned both for routine intensity-modulated radiation therapy (IMRT) QA and as a secondary check for the Eclipse VersaHD model. The Eclipse-generated VersaHD model was in excellent agreement with the measured PDD curves and beam profiles. The measured leaf transmission factors were less than 0.5% for all energies. The model validation study yielded absolute point dose agreement between ionization chamber measurements and Eclipse within ±4% for all cases. The comparison between Mobius and Eclipse, and between Mobius and ionization chamber measurements lead to absolute point dose agreement within ±5%. The corresponding 3D dose distributions evaluated with 3%global/2mm gamma criteria resulted in larger than 90% passing rates for all plans. The Eclipse TPS can model VersaHD LINACs with clinically acceptable accuracy. The model validation study and comparisons with Mobius demonstrated that the modeling of VersaHD in Eclipse necessitates further improvement to provide dosimetric accuracy on par with Varian LINACs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials