Evidence map›Paper›PMID 31471844›Full record

Trial reportInternational urology and nephrology2019

Reversed connection of cuffed, tunneled, dual-lumen catheters with increased blood flow rate maintains the adequacy of delivered dialysis despite the higher access recirculation.

Varvara Kousoula, Panagiotis I Georgianos, Konstantinos Mavromatidis, Christos Syrganis, Elias Thodis, Stylianos Panagoutsos, Ploumis Passadakis

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in International urology and nephrology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Varvara KousoulaTherapeutiki Dialysis Unit, Chalkidikis St 77, 542 48, Thessaloniki, Greece. barbkous@hotmail.com.
Panagiotis I GeorgianosTherapeutiki Dialysis Unit, Chalkidikis St 77, 542 48, Thessaloniki, Greece.
Konstantinos MavromatidisRenal Department, General Hospital of Komotini, Komotini, Greece.
Christos SyrganisHemodialysis Unit, Achillopouleion General Hospital of Volos, Volos, Greece.
Elias ThodisDepartment of Nephrology, School of Medicine, Democritus University of Thrace, Alexandroupoli, Greece.
Stylianos PanagoutsosDepartment of Nephrology, School of Medicine, Democritus University of Thrace, Alexandroupoli, Greece.
Ploumis PassadakisDepartment of Nephrology, School of Medicine, Democritus University of Thrace, Alexandroupoli, Greece.
Democritus University of Thrace · GRAgios Pavlos General Hospital · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeReversing the connection mode of permanent dual-lumen dialysis catheters results in higher access recirculation that may compromise the dialysis adequacy. The purpose of this study is to investigate the effect of reversed-connected dialysis with a higher versus a standard blood flow rate (Qb) on adequacy parameters and access recirculation. MATERIALS AND

methodsIn a cross-over design, 46 prevalent dialysis patients with a properly functioning cuffed, tunneled, dual-lumen catheter were evaluated in three consecutive mid-week dialysis sessions. At baseline, participants were evaluated under standardized conditions (correct connection, Qb = 300 ml/min). In Phase A, dialysis was performed with reversed connection and Qb = 300 ml/min. In Phase B, dialysis was performed with reversed connection and Qb = 400 ml/min. The sequence of evaluations (Phase A and B or vise verse) was randomized. All other dialysis-related parameters were unchanged in all three occasions.

resultsAs expected, compared with baseline, reversed-connected dialysis in Phase A resulted in lower URR and spKt/V, and in a higher recirculation rate. Compared with baseline, reversed-connected dialysis with a higher Qb in Phase B resulted in an even higher recirculation rate, but the parameters of dialysis adequacy were not different. Increase in Qb from 300 to 400 ml/min resulted in an improvement of the dialysis adequacy (URR: 64.1 ± 7.8% vs. 70.6 ± 8.2%, P < 0.001; spKt/V: 1.22 ± 0.3 vs. 1.45 ± 0.3, P < 0.001) despite the higher recirculation rate.

conclusionThis study suggests that reversed-connected dialysis with increasing Qb maintains the adequacy of the delivered dialysis despite the compensatory increase in recirculation.

Indexed as

Blood Flow VelocityCatheters, IndwellingAgedAged, 80 and overCross-Over StudiesEquipment DesignFemaleHumansMaleRenal DialysisAdequacyCentral venous catheterDialysisRecirculation

Identifiers

PMID31471844
OpenAlexW2970613387

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.