Evidence map›Paper›PMID 31469317›Full record

ArticleDento maxillo facial radiology2020

Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position.

Gustavo Machado Santaella, Pedro Luiz Rosalen, Polyane Mazucatto Queiroz, Francisco Haiter-Neto, Ann Wenzel, Rubens Spin-Neto

Abstract read
In one paragraph

Article in Dento maxillo facial radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Gustavo Machado SantaellaDepartment of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil.ORCID http://orcid.org/0000-0002-0884-2443
Pedro Luiz RosalenDepartment of Physiological Sciences, Area of Pharmacology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil.
Polyane Mazucatto QueirozDepartment of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil.
Francisco Haiter-NetoDepartment of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil.
Ann WenzelDepartment of Dentistry and Oral Health, Section of Oral Radiology, Aarhus University, Denmark, Europe.
Rubens Spin-NetoDepartment of Dentistry and Oral Health, Section of Oral Radiology, Aarhus University, Denmark, Europe.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo assess the effect of CBCT detector position (aligned/lateral-offset) on image technical parameters (mean voxel value - MVV, standard deviation of voxel value (SDVV) distribution), comparing peripheral regions of interest (ROIs) to the central ROI in CBCT volumes.

methods40 CBCT volumes of a wax phantom were acquired in six units with aligned and/or lateral-offset detectors: Cranex 3Dx (CRA), Ortophos SL (ORT), Picasso Trio (PIC), Promax 3D Mid (PRO), Scanora 3D (SCA), and X1. Four image-acquisition protocols used an aligned detector, and four a lateral-offset detector. In each volume, 13 ROIs (12 peripheral and 1 central) were evaluated. MVV and SDVV of the peripheral ROI were compared to those of the central ROI in the volume. MVVD (the difference in percentage, between the MVV of a peripheral and the central ROI) was calculated.

resultsFor aligned-detectors, MVV increased (ORT and PRO) or decreased (CRA and X1) in the ROIs farther from the centre. For lateral-offset detectors, ROIs farther from the centre showed increased MVV. SDVV for most aligned detectors was lower, the nearer the ROI was to the centre. For lateral-offset detectors, it was lower for the peripheral ROIs, except with PIC. Range for MVVD was -32.8% to 22.8% for units with aligned detectors, and -20.7% to 69.5% for lateral-offset detectors.

conclusionLateral-offset detectors to acquire CBCT images significantly change SDVV distribution within the field-of-view, and lead to MVVD with increased range, compared to aligned detectors. This must be taken in consideration in the clinic, if voxel-value dependent measurements are to be performed.

Indexed as

Cone-Beam Computed TomographyRadiography, Dental, DigitalSpiral Cone-Beam Computed TomographyHumansPhantoms, Imagingcone beam computed tomographyquality control

Identifiers

PMID31469317
PMCPMC7026930

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.