Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position.
Article in Dento maxillo facial radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- What Drives Metal Artifacts in CBCT? A Comparative Study of Detector Types and Metallic Object Configurations.Radiology research and practice · 2026Article
- Gray values and noise behavior of cone-beam computed tomography machines-an in vitro study.Dento maxillo facial radiology · 2025Article
- Sivan classification system for diagnosis of jaw lesions based on visual volumetric analysis of 3-dimensional cone-beam computed tomographic images.Scientific reports · 2024Article
- A carbon nanotube x-ray source array designed for a new multisource cone beam computed tomography scanner.Physics in medicine and biology · 2024Article
- Cone-beam computed tomography-based radiographic considerations in impacted lower third molars: Think outside the box.Imaging science in dentistry · 2023Article
- Impact of movement and motion-artefact correction on image quality and interpretability in CBCT units with aligned and lateral-offset detectors.Dento maxillo facial radiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo assess the effect of CBCT detector position (aligned/lateral-offset) on image technical parameters (mean voxel value - MVV, standard deviation of voxel value (SDVV) distribution), comparing peripheral regions of interest (ROIs) to the central ROI in CBCT volumes.
methods40 CBCT volumes of a wax phantom were acquired in six units with aligned and/or lateral-offset detectors: Cranex 3Dx (CRA), Ortophos SL (ORT), Picasso Trio (PIC), Promax 3D Mid (PRO), Scanora 3D (SCA), and X1. Four image-acquisition protocols used an aligned detector, and four a lateral-offset detector. In each volume, 13 ROIs (12 peripheral and 1 central) were evaluated. MVV and SDVV of the peripheral ROI were compared to those of the central ROI in the volume. MVVD (the difference in percentage, between the MVV of a peripheral and the central ROI) was calculated.
resultsFor aligned-detectors, MVV increased (ORT and PRO) or decreased (CRA and X1) in the ROIs farther from the centre. For lateral-offset detectors, ROIs farther from the centre showed increased MVV. SDVV for most aligned detectors was lower, the nearer the ROI was to the centre. For lateral-offset detectors, it was lower for the peripheral ROIs, except with PIC. Range for MVVD was -32.8% to 22.8% for units with aligned detectors, and -20.7% to 69.5% for lateral-offset detectors.
conclusionLateral-offset detectors to acquire CBCT images significantly change SDVV distribution within the field-of-view, and lead to MVVD with increased range, compared to aligned detectors. This must be taken in consideration in the clinic, if voxel-value dependent measurements are to be performed.