ArticleJournal of clinical monitoring and computing2020
Detecting intraoperative gastric regurgitation by using preattached esophageal multichannel intraluminal impedance and pH monitoring on a solid-state manometry: a case series study.
Article in Journal of clinical monitoring and computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 3 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Adequate barrier pressure (BrP), calculated by subtracting intragastric pressure (IGP) from lower esophageal sphincter pressure (LESP), is believed to prevent gastroesophageal regurgitation (GER). However, the occurrence of intraoperative GER, the height and acidity it reached, have rarely been demonstrated simultaneously along with BrP. In this study, we developed preattached multichannel intraluminal impedance monitoring combined with pH-metry (the gold standard for detecting both height and acidity) on a solid-state manometry to continuously detect intraoperative GER as well as BrP changes. We used this system to record LESP, IGP, and changes in impedance through multichannel sensors and pH in patients receiving elective gynecological laparoscopy with laparoscopic pneumoperitoneum and Trendelenburg (LPT) positioning. Changes in BrP were analyzed at three time points (T1: before LPT; T2: during LPT when LESP reached its peak; and T3: after the offset of LPT). Our results indicated that this preattached experimental setup is feasible for intraoperative applications. GER was not detected in our patients throughout LPT. The mean LESP at T2 (23.22 mmHg) was significantly higher than at T1 (13.23 mmHg), but comparable to that at T3 (18.91 mmHg). The mean IGP (3.24 mmHg) at T2 was significantly higher than at T1 and T3 (- 6.10 and - 2.25 mmHg, respectively). The mean BrP scores were comparable from T1 to T3 (T1: 19.34 mmHg; T2: 19.98 mmHg; T3: 21.16 mmHg). Based on our results, the proposed setup is helpful for intraoperative monitoring and management of patients at high risk of GER.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.