ArticleInternational journal of dentistry2019

Plasma Sterilization Effectively Reduces Bacterial Contamination in Dental Unit Waterlines.

Sarocha Noopan, Phattranit Unchui, Supitcha Techotinnakorn, Ruchanee Salingcarnboriboon Ampornaramveth

Abstract read
In one paragraph

Article in International journal of dentistry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. [Advances in Novel Disinfection Technologies for Biofilm-Associated Nosocomial Infections].Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition · 2025
    Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Dental unit water content and antibiotic resistance ofJournal of oral microbiology · 2022
    Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sarocha NoopanResearch Unit on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Phattranit UnchuiResearch Unit on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Supitcha TechotinnakornResearch Unit on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Ruchanee Salingcarnboriboon AmpornaramvethResearch Unit on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0000-0002-5652-3092

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate the effectiveness of plasma sterilization in reducing bacterial contamination and controlling biofilms in dental unit waterlines. MATERIALS AND

methodsTen identical dental chair units (DCUs) were used. Five DCUs were installed with an automated plasma sterilization system (PSS) and the other five were kept as nontreated controls (CTL). Water flushed from the airotor line served as the output water of the dental unit waterlines (DUWLs). Water samples were collected at the beginning and on a weekly basis for 4 months. Water was analyzed for bacterial contamination (CFU/mL). Scanning electron microscopy (SEM) was used to investigate the amount of biofilm in the waterlines. Biofilm viability was assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assays. All statistical analyses were performed using the Mann-Whitney

resultsThe DCU output water was found to be heavily contaminated with bacteria. Plasma sterilization effectively reduced bacterial contamination from an average of 212 CFU/mL to 8 CFU/mL. During the entire period of 4 months, the level remained below 500 CFU/mL, the standard level recommended by the Centers for Disease Control and Prevention (CDC) of the USA. The reduction in the bacterial count was significant compared with the CTL group (

conclusionPlasma sterilization, which is part of electrochemically activated water, effectively reduces bacterial contamination and reduces biofilms in dental unit waterlines.