Evidence map›Paper›PMID 31463121›Full record

ArticleJournal of thoracic disease2019

Interobserver size measurement variability in part-solid lung adenocarcinoma using pre-operative computed tomography.

Kazutoshi Hamanaka, Hiroki Takayama, Tsutomu Koyama, Shunichiro Matsuoka, Tetsu Takeda, Hiroyuki Agatsuma, Kyoko Yamada, Akira Hyogotani, Satoshi Kawakami, Ken-Ichi Ito

Abstract read
In one paragraph

Article in Journal of thoracic disease, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kazutoshi HamanakaDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Hiroki TakayamaDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Tsutomu KoyamaDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Shunichiro MatsuokaDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Tetsu TakedaDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Hiroyuki AgatsumaDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Kyoko YamadaDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Akira HyogotaniDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.
Satoshi KawakamiDepartment of Radiology, Shinshu University School of Medicine, Nagano, Japan.
Ken-Ichi ItoDepartment of Thoracic Surgery, Shinshu University School of Medicine, Nagano, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn the current lung cancer tumor-node-metastasis classification, solid tumor size is used for tumor diameter measurement as the dense component. However, measuring solid tumor size is sometimes difficult and inter-observer variability may increase, particularly in part-solid nodules with ground-glass opacity (GGO). This study aimed to investigate inter-observer size measurement variability in lung adenocarcinoma.

methodsOf 47 patients with part-solid lung adenocarcinoma who had undergone surgery at our department from January to December 2016, five surgeons and one radiologist undertook unidimensional solid and total size tumor measurements using pre-operative axial computed tomography images, and we assessed inter-observer size measurement variability. Variability was then subclassified into five groups, according to computer tomography-identified tumor morphological characteristics, namely: (I) minimally invasive; (II) peribronchovascular; (III) spiculation/atelectasis; (IV) adjacent to cystic lesion, and; (V) diffuse consolidation and GGO.

resultsThe mean inter-observer variability was 9.7 mm (solid size) and 7.7 mm (total size). Analysis of the maximum and minimum measurement size values for each patient undertaken showed that the most experienced surgeon and the radiologist measured the minimum size more frequently. To correct for differences in mean tumor diameter in each group, a comparison was made using a coefficient of variation (CV) calculated as the ratio of the standard deviation to the mean. Group I characteristics showed the largest coefficient value for variation in solid size measurement.

conclusionsInter-observer measurement variability for solid size was larger than for total size in lung adenocarcinoma. Large variability in group I indicated the difficulty of size measurement for low-grade malignant potential nodules such as adenocarcinoma in situ, minimally invasive adenocarcinoma, and early-stage invasive adenocarcinoma. The possibility of unavoidable size measurement variability should be recognized when deciding on surgical procedures for these diseases.

Indexed as

adenocarcinoma in situ (AIS)computed tomography (CT)Inter-observer variabilitylung adenocarcinoma

Identifiers

PMID31463121
PMCPMC6688035

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.