Evidence map›Paper›PMID 31458975›Full record

ArticleACS omega2018

Top-Down Fabricated Silicon Nanowire Arrays for Field-Effect Detection of Prostate-Specific Antigen.

Dipti Rani, Vivek Pachauri, Narayanan Madaboosi, Pawan Jolly, Xuan-Thang Vu, Pedro Estrela, Virginia Chu, João Pedro Conde, Sven Ingebrandt

Open access · goldAbstract read
In one paragraph

Article in ACS omega, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 40 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Article
  10. Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Dipti RaniDepartment of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482 Zweibrücken, Germany.
Vivek PachauriDepartment of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482 Zweibrücken, Germany.
Narayanan MadaboosiINESC Microsistemas e Nanotecnologias, Rua Alves Redol, 91000-029 Lisbon, Portugal.
Pawan JollyDepartment of Electronic and Electrical Engineering, University of Bath, BA2 7AY Bath, United Kingdom.
Xuan-Thang VuDepartment of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482 Zweibrücken, Germany.
Pedro EstrelaDepartment of Electronic and Electrical Engineering, University of Bath, BA2 7AY Bath, United Kingdom.
Virginia ChuINESC Microsistemas e Nanotecnologias, Rua Alves Redol, 91000-029 Lisbon, Portugal.
João Pedro CondeINESC Microsistemas e Nanotecnologias, Rua Alves Redol, 91000-029 Lisbon, Portugal.
Sven IngebrandtDepartment of Informatics and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482 Zweibrücken, Germany.
University of Applied Sciences Kaiserslautern · DEInstituto de Engenharia de Sistemas e Computadores Microsistemas e Nanotecnologias · PTUniversity of Bath · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Highly sensitive electrical detection of biomarkers for the early stage screening of cancer is desired for future, ultrafast diagnostic platforms. In the case of prostate cancer (PCa), the prostate-specific antigen (PSA) is of prime interest and its detection in combination with other PCa-relevant biomarkers in a multiplex approach is advised. Toward this goal, we demonstrate the label-free, potentiometric detection of PSA with silicon nanowire ion-sensitive field-effect transistor (Si NW-ISFET) arrays. To realize the field-effect detection, we utilized the DNA aptamer-receptors specific for PSA, which were covalently and site-specifically immobilized on Si NW-ISFETs. The platform was used for quantitative detection of PSA and the change in threshold voltage of the Si NW-ISEFTs was correlated with the concentration of PSA. Concentration-dependent measurements were done in a wide range of 1 pg/mL to 1 μg/mL, which covers the clinical range of interest. To confirm the PSA-DNA aptamer binding on the Si NW surfaces, a sandwich-immunoassay based on chemiluminescence was implemented. The electrical approach using the Si NW-ISFET platform shows a lower limit of detection and a wide dynamic range of the assay. In future, our platform should be utilized to detect multiple biomarkers in one assay to obtain more reliable information about cancer-related diseases.

Identifiers

PMID31458975
PMCPMC6644640
OpenAlexW2885497569

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.