Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade.

Saverio Latteri, Giuseppe Stella, Anna M Gueli, Stefania Mazzaglia, Valentina Palumbo, Tommaso Guastella

Open access · hybridAbstract readTechnical Report
In one paragraph

Article in Surgical laparoscopy, endoscopy & percutaneous techniques, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Saverio LatteriDepartment of Surgical Sciences and Advanced Technologies "GF Ingrassia".
Giuseppe StellaPHysics for Dating Diagnostics Dosimetry Research and Applications (PH3DRA) Laboratories, Department of Physics and Astronomy "Ettore Majorana," University of Catania & INFN Sez Catania, Catania, Italy.
Anna M GueliPHysics for Dating Diagnostics Dosimetry Research and Applications (PH3DRA) Laboratories, Department of Physics and Astronomy "Ettore Majorana," University of Catania & INFN Sez Catania, Catania, Italy.
Stefania MazzagliaPHysics for Dating Diagnostics Dosimetry Research and Applications (PH3DRA) Laboratories, Department of Physics and Astronomy "Ettore Majorana," University of Catania & INFN Sez Catania, Catania, Italy.
Valentina PalumboDepartment of Surgical Sciences and Advanced Technologies "GF Ingrassia".
Tommaso GuastellaDepartment of Surgical Sciences and Advanced Technologies "GF Ingrassia".
University of Catania · ITIstituto Nazionale di Fisica Nucleare, Sezione di Catania · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultrasonic devices disperse less energy in the tissues. The new Harmonic Focus+ (HF+) seems to be more efficient but thermal damages have been reported. This study examined the temperature and the emissivity profile of the active and passive blades of the HF+, on a pig tissue model at different power settings. The FLIR System B series thermal imaging camera has been used on various biological pig tissues to evaluate the emissivity of the ultrasonic device. The active blade heats up faster than the passive one and the increase in power increases the speed of the temperature raising only on the active blade. Increasing the power setting reduces the dissection time and the temperature of both blades. Active blade temperatures of <60°C are obtained with cutting times close to 5 seconds; with these cutting times, the inactive blade does not exceed 30°C. The HF+ emissivity profiles demonstrate that the behavior of the inactive blade is significantly different from the active one. To prevent thermal damages, keep the active blade toward the operator, do not exceed 5 seconds of activation, use the maximum power, and avoid the use of the instrument as a dissector immediately after its activation.

Indexed as

AnimalsBurnsHot TemperatureLiverSafetySkinSus scrofaSwineThermographyTime FactorsUltrasonic Surgical Procedures

Identifiers

PMID31453911
PMCPMC6818976
OpenAlexW2971088390

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.