Evidence map›Paper›PMID 31452990›Full record

ArticleBiomedical optics express2019

Multi-phase level set algorithm based on fully convolutional networks (FCN-MLS) for retinal layer segmentation in SD-OCT images with central serous chorioretinopathy (CSC).

Yanan Ruan, Jie Xue, Tianlai Li, Danhua Liu, Hua Lu, Meirong Chen, Tingting Liu, Sijie Niu, Dengwang Li

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Yanan RuanShandong Key Laboratory of Medical Physics and Image Processing, Shandong Provincial Engineering and Technical Center of Light Manipulation, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.
Jie XueShandong Key Laboratory of Medical Physics and Image Processing, Shandong Provincial Engineering and Technical Center of Light Manipulation, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.
Tianlai LiShandong Key Laboratory of Medical Physics and Image Processing, Shandong Provincial Engineering and Technical Center of Light Manipulation, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.
Danhua LiuShandong Key Laboratory of Medical Physics and Image Processing, Shandong Provincial Engineering and Technical Center of Light Manipulation, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.
Hua LuShandong Key Laboratory of Medical Physics and Image Processing, Shandong Provincial Engineering and Technical Center of Light Manipulation, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.
Meirong ChenAffiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, Shandong 250014, P. R. China.
Tingting LiuShandong Eye Hospital, Shandong Eye Institute, Shandong Academy of Medical Science, Jinan, Shandong 250014, China.
Sijie NiuSchool of Information Science and Engineering, University of Jinan, Jinan, 250022, China.
Dengwang LiShandong Key Laboratory of Medical Physics and Image Processing, Shandong Provincial Engineering and Technical Center of Light Manipulation, School of Physics and Electronics, Shandong Normal University, Jinan, 250014, China.
Shandong Normal University · CNZero to Three · USShandong Eye Hospital · CNUniversity of Jinan · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As a function of the spatial position of the optical coherence tomography (OCT) image, retinal layer thickness is an important diagnostic indicator for many retinal diseases. Reliable segmentation of the retinal layer is necessary for extracting useful clinical information. However, manual segmentation of these layers is time-consuming and prone to bias. Furthermore, due to speckle noise, low image contrast, retinal detachment, and also irregular morphological features make the automatic segmentation task challenging. To alleviate these challenges, in this paper, we propose a new coarse-fine framework combining the full convolutional network (FCN) with a multiphase level set (named FCN-MLS) for automatic segmentation of nine boundaries in retinal spectral OCT images. In the coarse stage, FCN is used to learn the characteristics of specific retinal layer boundaries and achieve classification of four retinal layers. The boundaries are then extracted and the remaining boundaries are initialized based on a priori information about the thickness of the retinal layer. In order to prevent the overlapping of the segmentation interfaces, a regional restriction technique is used in the multi-phase level to evolve the boundaries to achieve fine nine retinal layers segmentation. Experimental results on 1280 B-scans show that the proposed method can segment nine retinal boundaries accurately. Compared with the manual delineation, the overall mean absolute boundary location difference and the overall mean absolute thickness difference were 5.88 ± 2.38μm and 5.81 ± 2.19μm, which showed a good consistency with manual segmentation by the physicians. Our experimental results also outperform state-of-the-art methods.

Identifiers

PMID31452990
PMCPMC6701532
OpenAlexW2956684337

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.