Evidence map›Paper›PMID 31452629›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology

Validation of Dolphin dosimetry in three dimensional patient-specific quality assurance programme.

Niyas Puzhakkal, Abdullah Kallikuzhiyil Kochunny, Dinesh Makuny, Arun Krishnan M P, Ranjith C Poyil, Vysakh Raveendran

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Niyas PuzhakkalDepartment of Medical Physics, MVR Cancer Centre & Research Institute, Kozhikode, Kerala, India.
Abdullah Kallikuzhiyil KochunnyDepartment of Physics, Farook College, Kozhikode, Kerala, India.
Dinesh MakunyDepartment of Medical Physics, MVR Cancer Centre & Research Institute, Kozhikode, Kerala, India.
Arun Krishnan M PDepartment of Medical Physics, MVR Cancer Centre & Research Institute, Kozhikode, Kerala, India.
Ranjith C PoyilDepartment of Medical Physics, MVR Cancer Centre & Research Institute, Kozhikode, Kerala, India.
Vysakh RaveendranDepartment of Medical Physics, MVR Cancer Centre & Research Institute, Kozhikode, Kerala, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThe aim of this study is to commission and validate Dolphin-Compass dosimetry as a patient-specific Quality Assurance (QA) device.

backgroundThe advancement of radiation therapy in terms of highly conformal delivery techniques demands a novel method of patient-specific QA. Dolphin-Compass system is a dosimetry solution capable of doing different QA in radiation therapy. MATERIALS AND

methodsDolphin, air-vented ionization detector array mounted on Versa-HD Linear Accelerator (LINAC) was used for measurements. The Compass is a dose computation algorithm which requires modelling of LINAC head similar to other Treatment Planning Systems (TPS). The dosimetry system was commissioned after measuring the required beam data. The validation was performed by comparison of treatment plans generated in Monaco TPS against the measurement data. Different types of simple, complex, static and dynamic radiation fields and highly conformal treatment plans of patients were used in this study.

resultsFor all field sizes, point doses obtained from Dolphin-Compass dosimetry were in good agreement with the corresponding TPS calculated values in most of the regions, except the penumbra, outside field and at build-up depth. The results of gamma passing rates of measurements by using different Multi-leaf Collimator patterns and Intensity Modulated Radiation Therapy fluence were also found to be in good correlation with the corresponding TPS values.

conclusionsThe commissioning and validation of dosimetry was performed with the help of various fields, MLC patterns and complex treatment plans. The present study also evaluated the efficiency of the 3D dosimetry system for the QA of complex treatment plans.

Indexed as

CompassDolphin detectorIMRTQATreatment plans

Identifiers

PMID31452629
PMCPMC6702462

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.