Subcutaneous implantable cardioverter defibrillators in patients with left ventricular assist devices: case report and comprehensive review.

María López-Gil, Adolfo Fontenla, Juan F Delgado, Daniel Rodríguez-Muñoz

Open access · goldAbstract read
In one paragraph

Article in European heart journal. Case reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Electromagnetic interference between implantable cardiac devices and continuous-flow left ventricular assist devices: a review.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2021
    Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

María López-GilCardiac Electrophysiology & Arrhythmia Unit, Cardiology Department, 12 de Octubre University Hospital, Avda de Córdoba s/n, Madrid, Spain.
Adolfo FontenlaCardiac Electrophysiology & Arrhythmia Unit, Cardiology Department, 12 de Octubre University Hospital, Avda de Córdoba s/n, Madrid, Spain.
Juan F DelgadoI+12 Investigation Institute, 12 de Octubre University Hospital, Avda de Córdoba s/n, Madrid, Spain.
Daniel Rodríguez-MuñozCardiac Electrophysiology & Arrhythmia Unit, Cardiology Department, 12 de Octubre University Hospital, Avda de Córdoba s/n, Madrid, Spain.
Research Institute Hospital 12 de Octubre · ESUniversidad Complutense de Madrid · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLeft ventricular assist devices (LVAD) are increasingly used in patients with advanced heart failure, many of whom have been or will be implanted with an implantable cardioverter defibrillator (ICD). Interaction between both devices is a matter of concern. Subcutaneous ICD (S-ICD) obtains its signals through subcutaneous vectors, which poses special challenges with regards to adequate performance following LVAD implantation. CASE SUMMARY: We describe the case of a 24-year-old man implanted with an S-ICD because of idiopathic dilated cardiomyopathy, severe biventricular dysfunction, and self-limiting sustained ventricular tachycardias. After the implantation of a HeartMate 3™ (Left Ventricular Assist System, Abbott) several months later, the S-ICD became useless because of inappropriate sensing due to electromagnetic interference and attenuation of QRS voltage. DISCUSSION: We reviewed the reported cases in PubMed about the concomitant use of S-ICD and LVAD. Seven case reports about the performance of S-ICD in patients with an LVAD were identified, with discordant results. From these articles, we analyse the potential causes for these differing results. Pump location and operating rates in LVAD, as well as changes in the subcutaneous-electrocardiogram detected by the S-ICD after LVAD implantation are related to sensing disturbances when used in the same patient.

Indexed as

Case reportElectromagnetic interferencesLeft ventricular assist devicesSubcutaneous implantable cardioverter defibrillatorUndersensing

Identifiers

PMID31449611
PMCPMC6601396
OpenAlexW2942554646

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.