Low dose cone-beam computed tomography reconstruction via hybrid prior contour based total variation regularization (hybrid-PCTV).

Yingxuan Chen, Fang-Fang Yin, Yawei Zhang, You Zhang, Lei Ren

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Low-dose CBCT image reconstruction: a review.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Yingxuan ChenMedical Physics Graduate Program, Duke University, Durham, NC, USA.
Fang-Fang YinMedical Physics Graduate Program, Duke University, Durham, NC, USA.
Yawei ZhangDepartment of Radiation Oncology, Duke University Medical Center, Durham, NC, USA.
You ZhangMedical Physics Graduate Program, Duke University, Durham, NC, USA.
Lei RenMedical Physics Graduate Program, Duke University, Durham, NC, USA.
Duke Medical Center · USDuke University · US

Funding

A Limited-angle Intra-fractional Verification (LIVE) System for SBRT TreatmentsR01CA184173 · NCI · DUKE UNIVERSITY · PI REN, LEI, YIN, FANG-FANG · 2015 to 2018
$1.5M
NCI NIH HHS R01 CA184173
6 · The paper itself

Abstract

backgroundPreviously, we developed a prior contour based total variation (PCTV) method to use edge information derived from prior images for edge enhancement in low-dose cone-beam computed tomography (CBCT) reconstruction. However, the accuracy of edge enhancement in PCTV is affected by the deformable registration errors and anatomical changes from prior to on-board images. In this study, we develop a hybrid-PCTV method to address this limitation to enhance the robustness and accuracy of the PCTV method.

methodsPlanning-CT is used as prior images and deformably registered with on-board CBCT reconstructed by the edge preserving TV (EPTV) method. Edges derived from planning CT are deformed based on the registered deformation vector fields to generate on-board edges for edge enhancement in PCTV reconstruction. Reference CBCT is reconstructed from the simulated projections of the deformed planning-CT. Image similarity map is then calculated between reference and on-board CBCT using structural similarity index (SSIM) method to estimate local registration accuracy. The hybrid-PCTV method enhances the edge information based on a weighted edge map that combines edges from both PCTV and EPTV methods. Higher weighting is given to PCTV edges at regions with high registration accuracy and to EPTV edges at regions with low registration accuracy. The hybrid-PCTV method was evaluated using both digital extended-cardiac-torso (XCAT) phantom and lung patient data. In XCAT study, breathing amplitude change, tumor shrinkage and new tumor were simulated from CT to CBCT. In the patient study, both simulated and real projections of lung patients were used for reconstruction. Results were compared with both EPTV and PCTV methods.

resultsEPTV led to blurring bony structures due to missing edge information, and PCTV led to blurring tumor edges due to inaccurate edge information caused by errors in the deformable registration. In contrast, hybrid-PCTV enhanced edges of both bone and tumor. In XCAT study using 30 half-fan CBCT projections, compared with ground truth, relative errors (REs) were 1.3%, 1.1% and 0.9% and edge cross-correlation were 0.66, 0.68 and 0.71 for EPTV, PCTV and hybrid-PCTV, respectively. Moreover, in the lung patient data, hybrid-PCTV avoided the wrong edge enhancement in the PCTV method while maintaining enhancements of the correct edges.

conclusionsHybrid-PCTV further improved the robustness and accuracy of PCTV by accounting for uncertainties in deformable registration and anatomical changes between prior and onboard images. The accurate edge enhancement in hybrid-PCTV will be valuable for target localization in radiation therapy.

Indexed as

Cone-beam computed tomography (CBCT)low dose reconstructiontotal variation

Identifiers

PMID31448208
PMCPMC6685814
OpenAlexW2953998632

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.