Evidence map›Paper›PMID 31444844›Full record

ArticleJournal of clinical laboratory analysis2020

Quantitation of estradiol by competitive light-initiated chemiluminescent assay using estriol as competitive antigen.

Jiuzhi Li, Liuxu Li, Ying Bian, Yang Yu, Zhonghua Qiang, Yuexiang Zhang, Huiqiang Li

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Six Decades of Research on Human Fetal Gonadal Steroids.International journal of molecular sciences · 2021
    Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jiuzhi LiSchool of Medical Laboratory, Tianjin Medical University, Tianjin, China.
Liuxu LiSchool of Medical Laboratory, Tianjin Medical University, Tianjin, China.
Ying BianSchool of Medical Laboratory, Tianjin Medical University, Tianjin, China.
Yang YuSchool of Medical Laboratory, Tianjin Medical University, Tianjin, China.
Zhonghua QiangSchool of Medical Laboratory, Tianjin Medical University, Tianjin, China.
Yuexiang ZhangDepartment of Clinical Laboratory, Tianjin Central Hospital of Obstetrics and Gynecology, Tianjin, China.
Huiqiang LiSchool of Medical Laboratory, Tianjin Medical University, Tianjin, China.ORCID https://orcid.org/0000-0003-1632-4598
Tianjin Medical University · CNTianjin Central Hospital of Gynecology Obstetrics · CN

Funding

National Natural Science Foundation of China 81772259
6 · The paper itself

Abstract

backgroundLight-initiated chemiluminescent assays (LICA) are homogeneous assays that are sensitive, specific, and free of separation and washing steps and have high throughput and high precision.

methodsIn this research, we developed a competitive method by LICA to achieve accurate quantification of estradiol (E2) in human serum. E2 competed with estriol (E3) for binding to anti-human E2 antibodies. E3 was linked to biotin via bovine serum albumin as a linker. As this assay used competition between the labeled tracer and the analyte, an increase in E2 concentration will cause a signal decrease.

resultsThe expected detection range of E2 was 20-5000 pg/mL. The analytical and functional sensitivities were 7.16 and 13.7 pg/mL, respectively. The intra- and inter-assay coefficients of variation were both below 15%, and the recovery rate ranged from 97.5% to 106.8%. The interference rates ranged from -3.6% to 5.4% and met detection requirements for E2 in hyperbilirubinemia, hemolysis, and lipemia in clinical samples. In addition, the cross-reactivity rates between E2 and structural analogs and some reproductive hormones varied from 1.9% to 10.6% which showed that LICA is highly specific for E2. Moreover, our results showed high accordance with the IMMULITE 2000 (y = 0.6695x + 47.92, r

conclusionOur data show that the LICA, which is easy to automate, is a promising technique for quantification of E2 in human serum and could be used for clinical detection.

Indexed as

LightAdolescentAdultAgedAntibodies, MonoclonalAntigensBilirubinBiotinylationCalibrationEstradiolEstriolFemaleHemoglobinsHumansLuminescent MeasurementsMiddle AgedAntibodies, MonoclonalAntigensBilirubinEstradiolEstriolHemoglobinsTriglyceridesequilibrium competitive assayestradiolestriollight-initiated chemiluminescent assayquantitative analysis

Identifiers

PMID31444844
PMCPMC6977107
OpenAlexW2969742612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.