Evidence map›Paper›PMID 31444624›Full record

ArticleInternational journal of computer assisted radiology and surgery2020

A comparison of thin-plate spline deformation and finite element modeling to compensate for brain shift during tumor resection.

Sarah Frisken, Ma Luo, Parikshit Juvekar, Adomas Bunevicius, Ines Machado, Prashin Unadkat, Melina M Bertotti, Matt Toews, William M Wells, Michael I Miga and 1 more

Open access · greenAbstract readComparative Study
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Intraoperative Registration by Cross-Modal Inverse Neural Rendering.Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention · 2024
    Article
  3. Learning Expected Appearances for Intraoperative Registration during Neurosurgery.Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Predicted Microscopic Cortical Brain Images for Optimal Craniotomy Positioning and Visualization.Computer methods in biomechanics and biomedical engineering. Imaging & visualization · 2020
    Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 4 institutions in 3 countries.

Sarah FriskenDepartment of Radiology, Brigham and Women's Hospital, Boston, MA, USA. sfrisken@bwh.harvard.edu.ORCID http://orcid.org/0000-0001-5731-5095
Ma LuoDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
Parikshit JuvekarDepartment of Neurosurgery, Brigham and Women's Hospital, Boston, MA, USA.
Adomas BuneviciusDepartment of Neurosurgery, Brigham and Women's Hospital, Boston, MA, USA.
Ines MachadoInstituto Superior Tecnico, Universidade de Lisboa, Lisbon, Portugal.
Prashin UnadkatDepartment of Neurosurgery, Brigham and Women's Hospital, Boston, MA, USA.
Melina M BertottiDepartment of Neurosurgery, Brigham and Women's Hospital, Boston, MA, USA.
Matt ToewsDépartement de Génie des Systems, Ecole de Technologie Superieure, Montreal, Canada.
William M WellsDepartment of Radiology, Brigham and Women's Hospital, Boston, MA, USA.
Michael I MigaDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
Alexandra J GolbyDepartment of Radiology, Brigham and Women's Hospital, Boston, MA, USA.
Brigham and Women's Hospital · USVanderbilt University · USÉcole de Technologie Supérieure · CAUniversity of Lisbon · PT

Funding

Image Guided Therapy Center - Ultrasound-based sensor system for the monitoring of COVID-19 patientsP41EB015898 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI TEMPANY, CLARE M · 2012 to 2021
$18.9M
Multimodal Registration of the Brain's Cortical SurfaceR01NS049251 · NINDS · VANDERBILT UNIVERSITY · PI GOLBY, ALEXANDRA J, MIGA, MICHAEL IAN · 2005 to 2018
$6.7M
Continuous Compensation of Brain Shift during NeurosurgeryR01EB027134 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI FRISKEN, SARAH · 2018 to 2021
$1.8M
National Institute of Health (US) P41-EB015898-09National Institute of Health (US) R01-EB027134-01National Institute of Health (US) R01-NS049251NIBIB NIH HHS P41 EB015898NIBIB NIH HHS R01 EB027134NINDS NIH HHS R01 NS049251
6 · The paper itself

Abstract

purposeBrain shift during tumor resection can progressively invalidate the accuracy of neuronavigation systems and affect neurosurgeons' ability to achieve optimal resections. This paper compares two methods that have been presented in the literature to compensate for brain shift: a thin-plate spline deformation model and a finite element method (FEM). For this comparison, both methods are driven by identical sparse data. Specifically, both methods are driven by displacements between automatically detected and matched feature points from intraoperative 3D ultrasound (iUS). Both methods have been shown to be fast enough for intraoperative brain shift correction (Machado et al. in Int J Comput Assist Radiol Surg 13(10):1525-1538, 2018; Luo et al. in J Med Imaging (Bellingham) 4(3):035003, 2017). However, the spline method requires no preprocessing and ignores physical properties of the brain while the FEM method requires significant preprocessing and incorporates patient-specific physical and geometric constraints. The goal of this work was to explore the relative merits of these methods on recent clinical data.

methodsData acquired during 19 sequential tumor resections in Brigham and Women's Hospital's Advanced Multi-modal Image-Guided Operating Suite between December 2017 and October 2018 were considered for this retrospective study. Of these, 15 cases and a total of 24 iUS to iUS image pairs met inclusion requirements. Automatic feature detection (Machado et al. in Int J Comput Assist Radiol Surg 13(10):1525-1538, 2018) was used to detect and match features in each pair of iUS images. Displacements between matched features were then used to drive both the spline model and the FEM method to compensate for brain shift between image acquisitions. The accuracies of the resultant deformation models were measured by comparing the displacements of manually identified landmarks before and after deformation.

resultsThe mean initial subcortical registration error between preoperative MRI and the first iUS image averaged 5.3 ± 0.75 mm. The mean subcortical brain shift, measured using displacements between manually identified landmarks in pairs of iUS images, was 2.5 ± 1.3 mm. Our results showed that FEM was able to reduce subcortical registration error by a small but statistically significant amount (from 2.46 to 2.02 mm). A large variability in the results of the spline method prevented us from demonstrating either a statistically significant reduction in subcortical registration error after applying the spline method or a statistically significant difference between the results of the two methods.

conclusionsIn this study, we observed less subcortical brain shift than has previously been reported in the literature (Frisken et al., in: Miller (ed) Biomechanics of the brain, Springer, Cham, 2019). This may be due to the fact that we separated out the initial misregistration between preoperative MRI and the first iUS image from our brain shift measurements or it may be due to modern neurosurgical practices designed to reduce brain shift, including reduced craniotomy sizes and better control of intracranial pressure with the use of mannitol and other medications. It appears that the FEM method and its use of geometric and biomechanical constraints provided more consistent brain shift correction and better correction farther from the driving feature displacements than the simple spline model. The spline-based method was simpler and tended to give better results for small deformations. However, large variability in the spline results and relatively small brain shift prevented this study from demonstrating a statistically significant difference between the results of the two methods.

Indexed as

Brain NeoplasmsFinite Element AnalysisHumansImaging, Three-DimensionalMagnetic Resonance ImagingNeuronavigationNeurosurgical ProceduresRetrospective StudiesUltrasonographyBrain shiftBrain shift compensationFinite element modelingImage-guided surgeryIntraoperative ultrasoundNeurosurgery

Identifiers

PMID31444624
PMCPMC6952552
OpenAlexW2969869402

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.