Evidence map›Paper›PMID 31444593›Full record

ArticleBiomechanics and modeling in mechanobiology2020

Pneumatic unidirectional cell stretching device for mechanobiological studies of cardiomyocytes.

Joose Kreutzer, Marlitt Viehrig, Risto-Pekka Pölönen, Feihu Zhao, Marisa Ojala, Katriina Aalto-Setälä, Pasi Kallio

Abstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Mechanobiological Dynamics-Inspired Mechanomodulatory Biomaterials.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Joose KreutzerMicro-and Nanosystems Research Group, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, 33720, Tampere, Finland. joose.kreutzer@tuni.fi.ORCID http://orcid.org/0000-0001-5964-8707
Marlitt ViehrigDepartment of Health Technology, Technical University of Denmark, 2800, Lyngby, Denmark.
Risto-Pekka PölönenHeart Group, Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön Katu 34, 33520, Tampere, Finland.
Feihu ZhaoDepartment of Biomedical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven, The Netherlands.
Marisa OjalaHeart Group, Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön Katu 34, 33520, Tampere, Finland.
Katriina Aalto-SetäläHeart Group, Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön Katu 34, 33520, Tampere, Finland.
Pasi KallioMicro-and Nanosystems Research Group, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, 33720, Tampere, Finland.

Funding

Tekes (FI) 40346/11
6 · The paper itself

Abstract

In this paper, we present a transparent mechanical stimulation device capable of uniaxial stimulation, which is compatible with standard bioanalytical methods used in cellular mechanobiology. We validate the functionality of the uniaxial stimulation system using human-induced pluripotent stem cells-derived cardiomyocytes (hiPSC-CMs). The pneumatically controlled device is fabricated from polydimethylsiloxane (PDMS) and provides uniaxial strain and superior optical performance compatible with standard inverted microscopy techniques used for bioanalytics (e.g., fluorescence microscopy and calcium imaging). Therefore, it allows for a continuous investigation of the cell state during stretching experiments. The paper introduces design and fabrication of the device, characterizes the mechanical performance of the device and demonstrates the compatibility with standard bioanalytical analysis tools. Imaging modalities, such as high-resolution live cell phase contrast imaging and video recordings, fluorescent imaging and calcium imaging are possible to perform in the device. Utilizing the different imaging modalities and proposed stretching device, we demonstrate the capability of the device for extensive further studies of hiPSC-CMs. We also demonstrate that sarcomere structures of hiPSC-CMs organize and orient perpendicular to uniaxial strain axis and thus express more maturated nature of cardiomyocytes.

Indexed as

BiophysicsCell ShapeDimethylpolysiloxanesHumansInduced Pluripotent Stem CellsMyocytes, CardiacSarcomeresStress, MechanicalbaysilonDimethylpolysiloxanesCardiomyocyteshiPSCMechanical stimulationPDMS

Identifiers

PMID31444593
PMCPMC7005075

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.