Evidence map›Paper›PMID 31444564›Full record

Trial reportInternational orthopaedics2019

Capsular fixation limits graft extrusion in lateral meniscal allograft transplantation.

Angel Masferrer-Pino, Joan C Monllau, Ferran Abat, Pablo E Gelber

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in International orthopaedics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 21 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Review
  8. MRI evaluation of the peripheral attachments of the lateral meniscal body: the menisco-tibio-popliteus-fibular complex.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022
    Article
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Angel Masferrer-PinoDepartment of Orthopedic Surgery and Traumatology, ICATME, Hospital Universitari Dexeus - Universitat Autònoma de Barcelona, Sabino Arana, 5-19, 08028, Barcelona, Spain.
Joan C MonllauDepartment of Orthopedic Surgery and Traumatology, ICATME, Hospital Universitari Dexeus - Universitat Autònoma de Barcelona, Sabino Arana, 5-19, 08028, Barcelona, Spain.
Ferran AbatReSport Clinic, Barcelona, Spain.
Pablo E GelberDepartment of Orthopedic Surgery and Traumatology, ICATME, Hospital Universitari Dexeus - Universitat Autònoma de Barcelona, Sabino Arana, 5-19, 08028, Barcelona, Spain. personal@drgelber.com.
Institut Català de Traumatologia i Medicina de l'Esport · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe main purpose of this investigation was to compare the amount of graft extrusion of lateral meniscal allograft transplantation (MAT) performed with a suture-only technique with or without a capsulodesis. Secondarily, the assessment of functional results was also covered. We hypothesized that capsular fixation reduces the post-operative degree of allograft extrusion and it does not affect the functional outcomes during the short-term follow-up period studied.

methodsProspective series of 29 lateral MAT. Fifteen were fixed with a suture-only technique (group A). The remaining 14 cases (group B) also included arthroscopic lateral capsular fixation (capsulodesis). Functional results were assessed with Lysholm, Tegner, and VAS for pain. Magnetic resonance imaging (MRI) was performed to determine the degree of meniscal extrusion. Millimeters of extrusion and percentage of extruded meniscal tissue were calculated for both groups. The degree of extrusion was considered minor if it was < 3 mm or major if it was > 3 mm.

resultsGroup A had 11 cases (73.3%) of major extrusion and group B had 4 cases (28.6%) (p = 0.02). The percentage of extruded meniscal tissue was 35% in group A and 24.6% in group B (p = 0.04). At a mean 3.4 years (range 1-4) post-operatively, the Lysholm score had a mean 89.60 ± 6.93 and 91.43 ± 6.19 points in groups A and B, respectively (p < 0.001). The median follow-up Tegner score improved from 4 (range 3-5) to 7 (range 6-9) in group A (p < 0.001) and from 4 (range 3-5) to 7 (range 6-8) in group B (p < 0.001). VAS dropped 5 and 7.3 points in groups A and B, respectively (p < 0.001). There were no complications in this series.

conclusionsIn lateral MAT with the suture-only fixation technique, the described capsulodesis minimized meniscal extrusion. In terms of functional results, there were no differences between the groups at a mean 3.4-year follow-up.

Indexed as

AdultAllograftsArthroscopyFemaleHumansJoint CapsuleKnee InjuriesMagnetic Resonance ImagingMaleMenisci, TibialMiddle AgedPlastic Surgery ProceduresProspective StudiesReoperationSuture TechniquesTransplantation, HomologousCapsulodesisKneeMeniscal extrusionMeniscal transplantationMeniscus

Identifiers

PMID31444564
OpenAlexW2969449393

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.