ArticleAdvances in therapy2019
One-Year Comparative Evaluation of iStent or iStent inject Implantation Combined with Cataract Surgery in a Single Center.
Article in Advances in therapy, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed.
- Clinical Outcomes of Trabecular Micro-Bypass Stent in Patients with Moderate-to-Severe Open-Angle Glaucoma.Korean journal of ophthalmology : KJO · 2026Article
- Multicentre study comparing ab-interno canaloplasty and trabecular micro-bypass stent in primary open-angle glaucoma.Eye (London, England) · 2026Article
- Comparison of surgical outcomes between iStent and iStent inject W with ≥2 years of follow-up: a propensity score matching analysis.Japanese journal of ophthalmology · 2026Article
- Cataract surgery with and without trabecular micro-bypass stent in primary angle-closure glaucoma: a multi-centre cohort study.Eye (London, England) · 2025Article
- Comparison Between Phacoemulsification-iStent Inject W and Phacoemulsification-Micropulse Transscleral Laser Therapy in Asian Eyes With Mild-Moderate Open Angle Glaucoma.Journal of glaucoma · 2025Article
- Evaluation of the effect of full-process blood glucose management on T2DM cataract patients based on visual electrophysiology and OCTA.Scientific reports · 2024Article
- Comparative evaluation of iStent versus iStent inject W combined with phacoemulsification in open angle glaucoma.PloS one · 2024Article
- Consistency in Standalone Canaloplasty Outcomes Using the iTrack Microcatheter.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
- Fellow-Eye Comparison between Phaco-Tanito Microhook Trabeculotomy and Phaco-iStent Inject W.Journal of clinical medicine · 2023Article
- Mid-Term Results of Ab Interno Trabeculectomy among Japanese Glaucoma Patients.Journal of clinical medicine · 2023Article
- Posture-Induced Intraocular Pressure Changes after iStent Inject W Combined with Phacoemulsification in Open Angle Glaucoma Patients.Medicina (Kaunas, Lithuania) · 2023Article
- Spotlight on Schlemm's Canal MicroStent Injection in Patients with Glaucoma.Clinical ophthalmology (Auckland, N.Z.) · 2023Review
- Updates on the Diagnosis and Management of Glaucoma.Mayo Clinic proceedings. Innovations, quality & outcomes · 2022Review
- iStent Trabecular Micro-bypass Stent Implantation Combined with Phacoemulsification for Open-Angle Glaucoma: A 2-Year Post-marketing Surveillance Study in Japan.Advances in therapy · 2022Observational
- Comparison of 1-year surgical outcomes of combined cataract surgery and gonioscopy-assisted transluminal trabeculotomy (GATT) versus cataract surgery and iStent Inject.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021Article
- iStent versus iStent inject implantation combined with phacoemulsification in open angle glaucoma.Indian journal of ophthalmology · 2021Article
- Outcomes of adjusted trabeculotomy in cases with juvenile glaucoma.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021Article
- Two-Year Comparative Outcomes of First- and Second-Generation Trabecular Micro-Bypass Stents with Cataract Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2021Article
- Treatment Success Across Different Levels of Preoperative Disease Burden: Stratified Two-Year Outcomes from the Pivotal Trial of iStentClinical ophthalmology (Auckland, N.Z.) · 2021Article
- Prospective Interventional Cohort Study of Ocular Surface Disease Changes in Eyes After Trabecular Micro-Bypass Stent(s) Implantation (iStent or iStent inject) with Phacoemulsification.Ophthalmology and therapy · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThis retrospective consecutive case series assessed 12-month effectiveness and safety of iStent
methodsEffectiveness outcomes consisted of intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving IOP < 18, < 15, or < 12 mmHg; and proportional analysis of medication usage. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA).
resultsThis evaluation included 58 eyes with OAG (35 iStent, 23 iStent inject), with 96.6% of eyes having mild or moderate glaucoma. Diagnoses included primary open-angle glaucoma (the majority; 72.4%), pseudoexfoliative glaucoma, and pigmentary glaucoma. Baseline mean IOP and medications were statistically comparable between groups: 16.1 ± 3.6 mmHg on a mean of 1.8 ± 0.8 medications in the iStent group, and 16.2 ± 3.1 mmHg on a mean of 1.7 ± 0.8 medications in the iStent inject group. Twelve months after stent-cataract surgery, mean IOP was significantly lower in the iStent inject group than in the iStent group (13.1 mmHg vs. 15.4 mmHg, respectively; p < 0.001), and the percent reduction in IOP from baseline was significantly greater in iStent inject eyes than in iStent eyes (19.1% vs. 4.3% reduction, respectively; p < 0.001). At 12 months postoperative, significantly greater proportions of iStent inject eyes than iStent eyes achieved IOP < 18 mmHg (100% vs. 80.0% of eyes, respectively; p = 0.035), IOP < 15 mmHg (73.9% vs. 34.3% of eyes, respectively; p = 0.003), and IOP < 12 mmHg (26.1% vs. 0% of eyes, respectively; p = 0.002). Meanwhile, both groups achieved significant medication reductions at 12 months vs. baseline (94.1% reduction in iStent inject eyes, p < 0.0001; and 72.2% reduction in iStent eyes, p < 0.0001), with the percent reduction being significantly greater in iStent inject eyes than in iStent eyes (p = 0.023). At 12 months, mean number of medications was significantly lower in iStent inject eyes than iStent eyes (0.1 vs. 0.5 medications, respectively; p = 0.021), and significantly more iStent inject eyes (95.7%) than iStent eyes (71.4%) were off medications entirely (p = 0.021). A similarly high safety profile was observed in both groups.
conclusioniStent or iStent inject implantation with cataract surgery resulted in substantial and safe reductions in IOP and medications through 12 months postoperative. Consistent with prior observations, greater efficacy was observed with iStent inject than with iStent.
fundingThe Rapid Service Fees were funded by Glaukos Corporation.