Evidence map›Paper›PMID 31440426›Full record

ArticleTranslational vision science & technology2019

Trade-Off Between Field-of-View and Resolution in the Thermal-Integrated Argus II System.

Yingchen He, Natalie T Huang, Avi Caspi, Arup Roy, Sandra R Montezuma

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Towards aJournal of neural engineering · 2022
    Article
  6. Article
  7. Article
  8. Optoelectronic Devices for Vision Restoration.Current ophthalmology reports · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Yingchen HeDepartment of Psychology, University of Minnesota, Minneapolis, MN, USA.
Natalie T HuangDepartment of Ophthalmology and Visual Neurosciences, University of Minnesota, Minneapolis, MN, USA.
Avi CaspiDepartment of Electrical and Electronic Engineering, Jerusalem College of Technology, Jerusalem, Israel.
Arup RoySecond Sight Medical Products, Inc., Sylmar, CA, USA.
Sandra R MontezumaDepartment of Ophthalmology and Visual Neurosciences, University of Minnesota, Minneapolis, MN, USA.
University of Minnesota · USJerusalem College of Technology · ILSecond Sight Medical Products · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the effect of a wider field-of-view (FOV) of a retinal prosthesis on the users' performance in locating objects.

methodsOne female and four male subjects who were blind due to end-stage retinitis pigmentosa and had been implanted with the Argus II retinal prosthesis participated (aged 63.4 ± 15.4). Thermal imaging was captured by an external sensor and converted to electrical stimulation to the retina. Subjects were asked to localize and to reach for heat-emitting objects using two different FOV mappings: a normal 1:1 mapping (no zoom) that provided 18° × 11° FOV and a 3:1 mapping (zoom out) that provided 49° × 35° FOV. Their accuracy and response time were recorded.

resultsSubjects were less accurate and took longer to complete the tasks with zoom out compared to no zoom. Localization accuracy decreased from 83% (95% confidence interval, 75%, 90%) with no zoom to 76% (67%, 83%) with zoom out (

conclusionsArgus II wearers can efficiently find heat-emitting objects with the default 18° × 11° FOV of the current Argus II. For spatial localization, a higher spatial resolution may be preferred over a wider FOV. TRANSLATIONAL RELEVANCE: Understanding the trade-off between FOV and spatial resolution in retinal prosthesis users can guide device optimization.

Indexed as

field-of-viewrehabilitationspatial resolutionultralow visionvisual prosthesis

Identifiers

PMID31440426
PMCPMC6701876
OpenAlexW2969382846

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.