Evidence map›Paper›PMID 31438861›Full record

Trial reportBMC anesthesiology2019

A comparison between the Disposcope endoscope and fibreoptic bronchoscope for nasotracheal intubation: a randomized controlled trial.

Junma Yu, Rui Hu, Lining Wu, Peng Sun, Zhi Zhang

Open access · goldAbstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in BMC anesthesiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Trial
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Junma YuHefei National Laboratory for Physical Sciences at the Microscale, Department of Biophysics and Neurobiology, University of Science and Technology of China, Hefei, 230027, People's Republic of China. majuny163@163.com.ORCID 0000-0003-4053-5942
Rui HuDepartment of Anesthesiology, The First People's Hospital of Hefei, Anhui Medical University, Hefei, Anhui, 230061, People's Republic of China.
Lining WuDepartment of Anesthesiology, The First People's Hospital of Hefei, Anhui Medical University, Hefei, Anhui, 230061, People's Republic of China.
Peng SunDepartment of Anesthesiology, The First People's Hospital of Hefei, Anhui Medical University, Hefei, Anhui, 230061, People's Republic of China.
Zhi ZhangHefei National Laboratory for Physical Sciences at the Microscale, Department of Biophysics and Neurobiology, University of Science and Technology of China, Hefei, 230027, People's Republic of China.
Anhui Medical University · CNUniversity of Science and Technology of China · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNasotracheal intubation (NTI) is frequently performed for oral and maxillofacial surgeries. This study evaluated whether NTI is easier when guided by Disposcope endoscopy or fibreoptic bronchoscopy.

methodsSixty patients (30 per group) requiring NTI were randomly assigned to undergo fibreoptic bronchoscopy-guided (fibreoptic group) or Disposcope endoscope-guided (Disposcope group) NTI. The NTI time, which was defined as the time from when the fibreoptic bronchoscope or aseptic suction catheter was inserted into the nasal cavity to the time at which the tracheal tube was correctly inserted through the glottis, was recorded. Epistaxis was evaluated by direct laryngoscopy five minutes after completing NTI and was scored as one of four grades according to the following modified criteria: no epistaxis, mild epistaxis, moderate epistaxis, and severe epistaxis.

resultsThe time to complete NTI was significantly longer in the fibreoptic group than in the Disposcope group (38.4 s vs 24.1 s; mean difference, 14.2 s; 95% confidence interval (CI), 10.4 to 18.1). Mild epistaxis was observed in 8 patients in the fibreoptic group and in 7 patients in the Disposcope group (26.7% vs 23.3%, respectively; relative risk, 1.2; 95% CI, 0.4 to 3.9), though no moderate or severe epistaxis occurred in either group. Furthermore, no obvious nasal pain was reported by any of the patients at any time point after extubation (P = 0.74).

conclusionNTI can be completed successfully using either fibreoptic bronchoscopy or Disposcope endoscope as a guide without any severe complications. However, compared to fibreoptic bronchoscopy, Disposcope endoscope requires less execution time (the NTI time).

trial registrationThis clinical research was registered at the Chinese Clinical Trial Registry ( www.chictr.org.cn , ChiCTR-IPR-17011462, date of registration, May 2017).

Indexed as

AdultBronchoscopesEndoscopesEpistaxisFemaleHumansIntubation, IntratrachealLaryngoscopyMaleMiddle AgedPainTime FactorsDisposcope endoscopeEndotracheal tubeFibreopticNasotracheal intubationVideo stylet

Identifiers

PMID31438861
PMCPMC6706907
OpenAlexW2969714080

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.