Evidence map›Paper›PMID 31437178›Full record

ArticlePloS one2019

Why -aVF can be used in STAN as a proxy for scalp electrode-derived signal; reply to comments by Kjellmer et al.

Tammo Delhaas, Peter Andriessen, Judith Oeh van Laar, Rik Vullings, Ben Jm Hermans, Hendrik J Niemarkt, Reint K Jellema, Daan Rmg Ophelders, Tim Gam Wolfs, Boris W Kramer and 1 more

Open access · goldAbstract readComment
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 90% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors at 4 institutions in 1 country.

Tammo DelhaasDepartment of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands.ORCID 0000-0001-6897-9700
Peter AndriessenDepartment of Pediatrics, Máxima Medical Centre, Veldhoven, the Netherlands.
Judith Oeh van LaarDepartment of Obstetrics and Gynecology, Máxima Medical Centre, Veldhoven, the Netherlands.
Rik VullingsSignal Processing Systems Group, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
Ben Jm HermansDepartment of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands.
Hendrik J NiemarktDepartment of Pediatrics, Máxima Medical Centre, Veldhoven, the Netherlands.
Reint K JellemaDepartment of Pediatrics, Máxima Medical Centre, Veldhoven, the Netherlands.
Daan Rmg OpheldersDepartment of Pediatrics, Maastricht University Medical Centre, Maastricht, the Netherlands.
Tim Gam WolfsDepartment of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands.
Boris W KramerDepartment of Pediatrics, Maastricht University Medical Centre, Maastricht, the Netherlands.
Alex ZwanenburgDepartment of Biomedical Engineering, Maastricht University, Maastricht, the Netherlands.
Radboud University Nijmegen · NLMaastricht University · NLMaastricht University Medical Centre · NLEindhoven University of Technology · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The conclusion of our recent paper that performance of the STAN device in clinical practice is potentially limited by high false-negative and high false-positive STAN-event rates and loss of ST waveform assessment capacity during severe hypoxemia, evoked comments by Kjellmer, Lindecrantz and Rosén. These comments can be summarized as follows: 1) STAN analysis is based on a unipolar lead but the authors used a negative aVF lead, and they did not validate this methodology; 2) The fetuses used in the study were too young to display the signals that the authors were trying to detect. In response to these comments we now provide both a theoretical and an experimental underpinning of our approach. In an in vivo experiment in human we placed several electrodes over the head (simulating different places of a scalp electrode), simultaneously recorded Einthoven lead I and II, and constructed -aVF from these two frontal leads. Irrespective of scalp electrode placement, the correlation between any of unipolar scalp electrode-derived signals and constructed-aVF was excellent (≥ 0.92). In response to the second comment we refer to a study which demonstrated that umbilical cord occlusion resulted in rapid increase in T/QRS ratio that coincided with initial hypertension and bradycardia at all gestational ages which were tested from 0.6-0.8 gestation. The animals of our study were in this gestational range and, hence, our experimental setup can be used to assess STAN's quality to detect fetal hypoxia. In conclusion, we have clearly demonstrated the appropriateness of using-aVF as a proxy for a scalp electrode-derived signal in STAN in these preterm lambs. Investigation why STAN could not detect relevant ST-changes and instead produced erroneous alarms in our experimental setup is hampered by the fact that the exact STAN algorithm (signal processing and analysis) is not in the public domain.

Indexed as

ElectrocardiographyScalpAnimalsElectrodesFemaleFetusHumansHypoxiaPregnancySheepUmbilical Cord

Identifiers

PMID31437178
PMCPMC6705853
OpenAlexW2969482550

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.