Evidence map›Paper›PMID 31434241›Full record

ReviewSensors (Basel, Switzerland)2019

Photoacoustic Imaging with Capacitive Micromachined Ultrasound Transducers: Principles and Developments.

Jasmine Chan, Zhou Zheng, Kevan Bell, Martin Le, Parsin Haji Reza, John T W Yeow

Abstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Ultrasound sensing with optical microcavities.Light, science & applications · 2024
    Review
  5. Review
  6. Review
  7. Review
  8. Photoacoustic imaging aided with deep learning: a review.Biomedical engineering letters · 2022
    Review
  9. Article
  10. Ultrasonic signal detection based on Fabry-Perot cavity sensor.Visual computing for industry, biomedicine, and art · 2021
    Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jasmine ChanDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Zhou ZhengDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Kevan BellDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Martin LeDepartment of Physics, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Parsin Haji RezaDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada. phajirez@uwaterloo.ca.
John T W YeowDepartment of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada. jyeow@uwaterloo.ca.ORCID 0000-0002-0740-8055

Funding

Natural Sciences and Engineering Research Council of Canada 0000000000
6 · The paper itself

Abstract

Photoacoustic imaging (PAI) is an emerging imaging technique that bridges the gap between pure optical and acoustic techniques to provide images with optical contrast at the acoustic penetration depth. The two key components that have allowed PAI to attain high-resolution images at deeper penetration depths are the photoacoustic signal generator, which is typically implemented as a pulsed laser and the detector to receive the generated acoustic signals. Many types of acoustic sensors have been explored as a detector for the PAI including Fabry-Perot interferometers (FPIs), micro ring resonators (MRRs), piezoelectric transducers, and capacitive micromachined ultrasound transducers (CMUTs). The fabrication technique of CMUTs has given it an edge over the other detectors. First, CMUTs can be easily fabricated into given shapes and sizes to fit the design specifications. Moreover, they can be made into an array to increase the imaging speed and reduce motion artifacts. With a fabrication technique that is similar to complementary metal-oxide-semiconductor (CMOS), CMUTs can be integrated with electronics to reduce the parasitic capacitance and improve the signal to noise ratio. The numerous benefits of CMUTs have enticed researchers to develop it for various PAI purposes such as photoacoustic computed tomography (PACT) and photoacoustic endoscopy applications. For PACT applications, the main areas of research are in designing two-dimensional array, transparent, and multi-frequency CMUTs. Moving from the table top approach to endoscopes, some of the different configurations that are being investigated are phased and ring arrays. In this paper, an overview of the development of CMUTs for PAI is presented.

Indexed as

capacitive micromachined ultrasound transducerphotoacoustic computed tomographyphotoacoustic endoscopyphotoacoustic microscopyphotoacoustic tomography

Identifiers

PMID31434241
PMCPMC6720758

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.