ArticleSensors (Basel, Switzerland)2019
Fiber Ring Laser Directional Torsion Sensor with Ultra-Wide Linear Response.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 19 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
In this paper, a comprehensive passive torsion measurement is performed firstly in a 40-cm-long polarization maintaining fiber-based Sagnac interferometer (PMF-SI), and the non-linear torsion response is found and investigated. Then, a fiber laser torsion sensor (FLTS) with a dual-ring-cavity structure is proposed and experimentally demonstrated, in which the PMF-SI is utilized as the optical filter as well as the sensing unit. In particular, the highly sensitive linear range is adjusted through fine phase modulation, and owing to the flat-top feature of fringes, an ~83.6% sensitivity difference is effectively compressed by the generated lasing. The experimental results show that, without any pre-twisting, the ultra-wide linear response from -175 to 175 rad/m is gained, and the torsion sensitivities are 2.46 and 1.55 nm/rad with high linearity (>0.99) in the clockwise and anti-clockwise directions, respectively. Additionally, a high extinction ratio (>42 dB) and small line-width (~0.14 nm) are obtained in the proposed FLTS, and the corresponding detection limit reaches 0.015 rad/m.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.