ArticleAnnals of laboratory medicine2020
Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay.
Article in Annals of laboratory medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Diagnostic Performance of New Commercial Interferon-Gamma Release Assays for Mycobacterium tuberculosis Infection: An Updated Systematic Review and Meta-analysis.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2026Pooled it
- Real-World Outcomes of Chemiluminescence Immunoassay Implementation forOpen forum infectious diseases · 2026Article
- Effect of Variability on Interferon-Gamma Release Assay Performance: A Quantitative Analysis.Annals of laboratory medicine · 2026Article
- Evaluation of diagnostic agreement between STANDARD E TB-Feron ELISA and TB-Feron FIA for tuberculosis infection in prison settings in Paraguay.Frontiers in public health · 2026Article
- Evaluation of three novel antigens and costimulatory agents for improvement of M. Tuberculosis specific interferon gamma release assays.BMC infectious diseases · 2025Article
- Review
- From immunology to artificial intelligence: revolutionizing latent tuberculosis infection diagnosis with machine learning.Military Medical Research · 2023Review
- Evaluation of a New Chemiluminescent Immunoassay-Based Interferon-Gamma Release Assay for Detection of Latent Tuberculosis Infection.Medicina (Kaunas, Lithuania) · 2023Article
- Evaluation of the Fully Automated Chemiluminescence Analyzer Liaison XL for the Performance of the QuantiFERON-TB Gold Plus Assay in an Area with a Low Incidence of Tuberculosis.Journal of clinical microbiology · 2021Article
- QuantiFERON-TB Gold Plus with Chemiluminescence Immunoassay: Do We Need a Higher Cutoff?Journal of clinical microbiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe interferon-gamma (IFN-γ) releasing assay (IGRA) is widely used for latent tuberculosis infection (LTBI) diagnosis. We evaluated the analytical performance of a new automated chemiluminescent immunoanalyzer-based IGRA (CLIA-IGRA), AdvanSure I3 (LG Life Sciences, Seoul, Korea) and compared it with that of the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay.
methodsRepeatability and reproducibility were evaluated at four levels. Detection capability, including limit of blank (LoB), limit of detection (LoD), and limit of quantification (LoQ), was evaluated using IFN-γ standard material (National Institute for Biological Standards and Control code: 87/586). Agreement between the results of two assays was evaluated using 341 blood samples from healthcare workers and patients at a tertiary care hospital. To determine the cut-off value of CLIA-IGRA for diagnosing LTBI, the ROC curve was analyzed.
resultsRepeatability and reproducibility were 4.86-7.00% and 6.36-7.88% CV, respectively. LoB, LoD, and LoQ were 0.022, 0.077, and 0.249 IU/mL, respectively. IFN-γ values between CLIA-IGRA and QFT-GIT showed a strong correlation within the analytical measurable range of both assays, especially when the value was low. Qualitative comparison of the two assays yielded a 99.1% overall agreement (kappa coefficient=0.98). A cut-off value of 0.35 IU/mL was appropriate for diagnosing LTBI.
conclusionsCLIA-IGRA is a reliable assay for LTBI diagnosis, with performance similar to that of QFT-GIT.