Evidence map›Paper›PMID 31429215›Full record

ArticleJournal of biomedical optics2019

Method for improving the spatial resolution of narrow x-ray beam-based x-ray luminescence computed tomography imaging.

Yueming Zhang, Michael C Lun, Changqing Li, Zhongxing Zhou

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Oxygenation imaging in deep tissue with X-Ray luminescence computed tomography (XLCT).Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  3. Superfast Scan of Focused X-Ray Luminescence Computed Tomography Imaging.IEEE access : practical innovations, open solutions · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. High-resolution x-ray luminescence computed tomography.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
  8. X-ray luminescence imaging for small animals.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
  9. Focused x-ray luminescence computed tomography: experimental studies.Proceedings of SPIE--the International Society for Optical Engineering · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yueming ZhangTianjin University, School of Precision Instruments and Optoelectronics Engineering, Tianjin, China.
Michael C LunUniversity of California, Department of Bioengineering, Merced, California, United States.
Changqing LiUniversity of California, Department of Bioengineering, Merced, California, United States.
Zhongxing ZhouTianjin University, School of Precision Instruments and Optoelectronics Engineering, Tianjin, China.

Funding

Life time imaging with pulsed x-ray based x-ray luminescence computed tomographyR01EB026646 · NIBIB · UNIVERSITY OF CALIFORNIA, MERCED · PI LI, CHANGQING · 2018 to 2021
$2.6M
NIBIB NIH HHS R01 EB026646
6 · The paper itself

Abstract

X-ray luminescence computed tomography (XLCT) is an emerging hybrid imaging modality which has the potential for achieving both high sensitivity and spatial resolution simultaneously. For the narrow x-ray beam-based XLCT imaging, based on previous work, a spatial resolution of about double the x-ray beam size can be achieved using a translate/rotate scanning scheme, taking step sizes equal to the x-ray beam width. To break the current spatial resolution limit, we propose a scanning strategy achieved by reducing the scanning step size to be smaller than the x-ray beam size. We performed four sets of numerical simulations and a phantom experiment using cylindrical phantoms and have demonstrated that our proposed scanning method can greatly improve the XLCT-reconstructed image quality compared with the traditional scanning approach. In our simulations, by using a fixed x-ray beam size of 0.8 mm, we were able to successfully reconstruct six embedded targets as small as 0.5 mm in diameter and with the same edge-to-edge distances by using a scanning step as small as 0.2 mm which is a 1.6 times improvement in the spatial resolution compared with the traditional approach. Lastly, the phantom experiment further demonstrated the efficacy of our proposed method in improving the XLCT image quality, with all image quality metrics improving as the step size decreased.

Indexed as

AlgorithmsComputer SimulationEquipment DesignImage Processing, Computer-AssistedLuminescenceModels, TheoreticalOptics and PhotonicsPhantoms, ImagingTomography, X-Ray ComputedX-Raysmedical optics instrumentationtomographyx-ray luminescence

Identifiers

PMID31429215
PMCPMC6698719

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked