Evidence map›Paper›PMID 31425612›Full record

SynthesisThe Cochrane database of systematic reviews2019

Nucleic acid and antigen detection tests for leptospirosis.

Bada Yang, Sophia G de Vries, Ahmed Ahmed, Benjamin J Visser, Ingeborg M Nagel, René Spijker, Martin P Grobusch, Rudy A Hartskeerl, Marga Ga Goris, Mariska Mg Leeflang

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it, 30 citations in OpenAlex.

  1. Nucleic acid and antigen detection tests for leptospirosis.The Cochrane database of systematic reviews · 2019
    Pooled it
  2. Trial
  3. Review
  4. Leptospirosis: An unusual cause of pulmonary haemorrhage and multi-organ failure.Lung India : official organ of Indian Chest Society · 2026
    Article
  5. Article
  6. Review
  7. Case Report: Leptospirosis Complicated by Persistent, Bilateral Sensorineural Hearing Loss.The American journal of tropical medicine and hygiene · 2023
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Epidemiology of Leptospirosis in Costa Rica 2011-2015.Current tropical medicine reports · 2017
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Bada YangDepartment of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam University Medical Centers, University of Amsterdam, Meibergdreef 9, Amsterdam, Noord-Holland, Netherlands, 1105 AZ.
Sophia G de Vries
Ahmed Ahmed
Benjamin J Visser
Ingeborg M Nagel
René Spijker
Martin P Grobusch
Rudy A Hartskeerl
Marga Ga Goris
Mariska Mg Leeflang
University of Amsterdam · NLAmsterdam University Medical Centers · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEarly diagnosis of leptospirosis may contribute to the effectiveness of antimicrobial therapy and early outbreak recognition. Nucleic acid and antigen detection tests have the potential for early diagnosis of leptospirosis. With this systematic review, we assessed the sensitivity and specificity of nucleic acid and antigen detection tests.

objectivesTo determine the diagnostic test accuracy of nucleic acid and antigen detection tests for the diagnosis of human symptomatic leptospirosis. SEARCH

methodsWe searched electronic databases including MEDLINE, Embase, the Cochrane Library, and regional databases from inception to 6 July 2018. We did not apply restrictions to language or time of publication. SELECTION CRITERIA: We included diagnostic cross-sectional studies and case-control studies of tests that made use of nucleic acid and antigen detection methods in people suspected of systemic leptospirosis. As reference standards, we considered the microscopic agglutination test alone (which detects antibodies against leptospirosis) or in a composite reference standard with culturing or other serological tests. Studies were excluded when the controls were healthy individuals or when there were insufficient data to calculate sensitivity and specificity. DATA COLLECTION AND ANALYSIS: At least two review authors independently extracted data from each study. We used the revised Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS-2) to assess risk of bias. We calculated study-specific values for sensitivity and specificity with 95% confidence intervals (CI) and pooled the results in a meta-analysis when appropriate. We used the bivariate model for index tests with one positivity threshold, and we used the hierarchical summary receiver operating characteristic model for index tests with multiple positivity thresholds. As possible sources of heterogeneity, we explored: timing of index test, disease prevalence, blood sample type, primers or target genes, and the real-time polymerase chain reaction (PCR) visualisation method. These were added as covariates to the meta-regression models. MAIN

resultsWe included 41 studies evaluating nine index tests (conventional PCR (in short: PCR), real-time PCR, nested PCR, PCR performed twice, loop-mediated isothermal amplification, enzyme-linked immunosorbent assay (ELISA), dot-ELISA, immunochromatography-based lateral flow assay, and dipstick assay) with 5981 participants (1834 with and 4147 without leptospirosis). Methodological quality criteria were often not reported, and the risk of bias of the reference standard was generally considered high. The applicability of findings was limited by the frequent use of frozen samples. We conducted meta-analyses for the PCR and the real-time PCR on blood products.The pooled sensitivity of the PCR was 70% (95% CI 37% to 90%) and the pooled specificity was 95% (95% CI 75% to 99%). When studies with a high risk of bias in the reference standard domain were excluded, the pooled sensitivity was 87% (95% CI 44% to 98%) and the pooled specificity was 97% (95% CI 60% to 100%). For the real-time PCR, we estimated a summary receiver operating characteristic curve. To illustrate, a point on the curve with 85% specificity had a sensitivity of 49% (95% CI 30% to 68%). Likewise, at 90% specificity, sensitivity was 40% (95% CI 24% to 59%) and at 95% specificity, sensitivity was 29% (95% CI 15% to 49%). The median specificity of real-time PCR on blood products was 92%. We did not formally compare the diagnostic test accuracy of PCR and real-time PCR, as direct comparison studies were lacking. Three of 15 studies analysing PCR on blood products reported the timing of sample collection in the studies included in the meta-analyses (range 1 to 7 days postonset of symptoms), and nine out of 16 studies analysing real-time PCR on blood products (range 1 to 19 days postonset of symptoms). In PCR studies, specificity was lower in settings with high leptospirosis prevalence. Other investigations of heterogeneity did not identify statistically significant associations. Two studies suggested that PCR and real-time PCR may be more sensitive on blood samples collected early in the disease stage. Results of other index tests were described narratively. AUTHORS'

conclusionsThe validity of review findings are limited and should be interpreted with caution. There is a substantial between-study variability in the accuracy of PCR and real-time PCR, as well as a substantial variability in the prevalence of leptospirosis. Consequently, the position of PCR and real-time PCR in the clinical pathway depends on regional considerations such as disease prevalence, factors that are likely to influence accuracy, and downstream consequences of test results. There is insufficient evidence to conclude which of the nucleic acid and antigen detection tests is the most accurate. There is preliminary evidence that PCR and real-time PCR are more sensitive on blood samples collected early in the disease stage, but this needs to be confirmed in future studies.

Indexed as

Antibodies, BacterialEnzyme-Linked Immunosorbent AssayHumansLeptospiraLeptospirosisNucleic AcidsPolymerase Chain ReactionROC CurveSensitivity and SpecificityAntibodies, BacterialNucleic Acids

Identifiers

PMID31425612
PMCPMC6699653
OpenAlexW2964658381

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.