Evidence map›Paper›PMID 31425362›Full record

ArticleEar and hearing

Improving Sensitivity of the Digits-In-Noise Test Using Antiphasic Stimuli.

Karina C De Sousa, De Wet Swanepoel, David R Moore, Hermanus Carel Myburgh, Cas Smits

Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07553481 (Chemotherapy-Induced Hearing Loss and Health Inequality), which is not on this map. Cited by 37 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
37citing papers in PubMed, 2 pooled it
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07553481 not yet recruitingnot on this map

Chemotherapy-Induced Hearing Loss and Health Inequality

TypeobservationalSponsorLancaster UniversityRan2026 to 2028Enrolled172ConditionsCancer, Chemo Brain, Chemotherapy, Hearing
3 · Its place in the literature

Who cites it

37 citing papers in PubMed, 2 syntheses or guidelines pooled it, 83 citations in OpenAlex.

  1. Pooled it
  2. Guideline
  3. Article
  4. Article
  5. Article
  6. Establishing New Pediatric Thresholds for Digits-In-Noise Testing.Laryngoscope investigative otolaryngology · 2025
    Article
  7. Article
  8. An Application-Based Hearing Assessment Among Medical Students Using Personal Listening Devices in a Private Medical College in South Chennai.Indian journal of community medicine : official publication of Indian Association of Preventive & Social Medicine · 2025
    Article
  9. Article
  10. Article
  11. Reliability Analysis of the Arabic Speech Matrix Test.Laryngoscope investigative otolaryngology · 2025
    Article
  12. Development and evaluation of the Digit Triplet Test in Swahili language.The South African journal of communication disorders = Die Suid-Afrikaanse tydskrif vir Kommunikasieafwykings · 2025
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Simplified cochlear frequency selectivity measure for sensorineural hearing loss screening: comparison with digit triplet test (DTT) and shortened speech, spatial and qualities of hearing scale (SSQ) questionnaire.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023
    Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 4 countries.

Karina C De SousaDepartment of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, Gauteng, South Africa.
De Wet SwanepoelDepartment of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, Gauteng, South Africa.
David R MooreCommunication Sciences Research Center, Cincinnati Childrens' Hospital Medical Center and Department of Otolaryngology, University of Cincinnati, Cincinnati, Ohio, USA.
Hermanus Carel MyburghDepartment of Electrical, Electronic and Computer Engineering, University of Pretoria, Pretoria, Gauteng, South Africa.
Cas SmitsAmsterdam UMC, Vrije Universiteit Amsterdam, Department of Otolaryngology-Head and Neck Surgery, Ear and Hearing, Amsterdam Public Health Research Institute, Amsterdam, The Netherlands.
University of Pretoria · ZACincinnati Children's Hospital Medical Center · US

Funding

Smartphone based detection and intervention for hearing loss in low and middle income countriesR21DC016241 · NIDCD · CINCINNATI CHILDRENS HOSP MED CTR · PI MOORE, DAVID, SWANEPOEL, DEWET · 2017 to 2018
$344k
NIDCD NIH HHS R21 DC016241
6 · The paper itself

Abstract

objectivesThe digits-in-noise test (DIN) has become increasingly popular as a consumer-based method to screen for hearing loss. Current versions of all DINs either test ears monaurally or present identical stimuli binaurally (i.e., diotic noise and speech, NoSo). Unfortunately, presentation of identical stimuli to each ear inhibits detection of unilateral sensorineural hearing loss (SNHL), and neither diotic nor monaural presentation sensitively detects conductive hearing loss (CHL). After an earlier finding of enhanced sensitivity in normally hearing listeners, this study tested the hypothesis that interaural antiphasic digit presentation (NoSπ) would improve sensitivity to hearing loss caused by unilateral or asymmetric SNHL, symmetric SNHL, or CHL.

designThis cross-sectional study recruited adults (18 to 84 years) with various levels of hearing based on a 4-frequency pure-tone average (PTA) at 0.5, 1, 2, and 4 kHz. The study sample was comprised of listeners with normal hearing (n = 41; PTA ≤ 25 dB HL in both ears), symmetric SNHL (n = 57; PTA > 25 dB HL), unilateral or asymmetric SNHL (n = 24; PTA > 25 dB HL in the poorer ear), and CHL (n = 23; PTA > 25 dB HL and PTA air-bone gap ≥ 20 dB HL in the poorer ear). Antiphasic and diotic speech reception thresholds (SRTs) were compared using a repeated-measures design.

resultsAntiphasic DIN was significantly more sensitive to all three forms of hearing loss than the diotic DIN. SRT test-retest reliability was high for all tests (intraclass correlation coefficient r > 0.89). Area under the receiver operating characteristics curve for detection of hearing loss (>25 dB HL) was higher for antiphasic DIN (0.94) than for diotic DIN (0.77) presentation. After correcting for age, PTA of listeners with normal hearing or symmetric SNHL was more strongly correlated with antiphasic (rpartial[96] = 0.69) than diotic (rpartial = 0.54) SRTs. Slope of fitted regression lines predicting SRT from PTA was significantly steeper for antiphasic than diotic DIN. For listeners with normal hearing or CHL, antiphasic SRTs were more strongly correlated with PTA (rpartial[62] = 0.92) than diotic SRTs (rpartial[62] = 0.64). Slope of the regression line with PTA was also significantly steeper for antiphasic than diotic DIN. The severity of asymmetric hearing loss (poorer ear PTA) was unrelated to SRT. No effect of self-reported English competence on either antiphasic or diotic DIN among the mixed first-language participants was observed.

conclusionsAntiphasic digit presentation markedly improved the sensitivity of the DIN test to detect SNHL, either symmetric or asymmetric, while keeping test duration to a minimum by testing binaurally. In addition, the antiphasic DIN was able to detect CHL, a shortcoming of previous monaural or binaurally diotic DIN versions. The antiphasic DIN is thus a powerful tool for population-based screening. This enhanced functionality combined with smartphone delivery could make the antiphasic DIN suitable as a primary screen that is accessible to a large global audience.

Indexed as

Hearing Loss, SensorineuralNoiseAdultCross-Sectional StudiesHearing TestsHumansReproducibility of Results

Identifiers

PMID31425362
PMCPMC7015780
OpenAlexW2967556793

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.