Evidence map›Paper›PMID 31425068›Full record

ArticleIEEE transactions on medical imaging2020

Analytic Determination of Rectangular-Pinhole Sensitivity With Penetration.

Scott D Metzler, Stephen C Moore

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Scott D Metzler
Stephen C Moore
University of Pennsylvania · US

Funding

Development of a High Performance Clinical Cardiac SPECT/TCT SystemR01HL108119 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI METZLER, SCOTT DEAN · 2012 to 2020
$7.3M
Preclinical cardiac imaging package for clinical SPECT systemsR01HL111883 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI METZLER, SCOTT DEAN, MOORE, STEPHEN C. · 2012 to 2015
$2.8M
NHLBI NIH HHS R01 HL108119NHLBI NIH HHS R01 HL111883
6 · The paper itself

Abstract

Modern small-animal SPECT systems use multiple pinhole collimators per detector to increase sensitivity while still maintaining high resolution. This resolution is a combination of aperture resolution combined with detector resolution, which is mitigated by magnification. Higher magnification results in better resolution, but fewer apertures per detector. When multiple pinhole collimators project onto the same detector, those with a rectangular field of view (FOV) can be packed more tightly than those with a circular FOV. In addition, a rectangular aperture can be used to obtain different resolution-sensitivity tradeoffs in the two orthogonal directions. Thus, these rectangular-pinhole collimators can have independent FOVs and independent resolution values in the two directions of the rectangular aperture. Previous work has determined the amount of penetration for circular pinholes (i.e., circular apertures with circular FOVs), where the pinhole walls were modeled as cones. In this work, a formula for the penetrative sensitivity for rectangular apertures with a rectangular FOV is determined. The formula was validated using numerical calculations for various combinations of acceptance angles, aperture sizes, linear attenuation coefficients, and incidence angles.

Indexed as

AnimalsImage Processing, Computer-AssistedTomography, Emission-Computed, Single-Photon

Identifiers

PMID31425068
PMCPMC7241287
OpenAlexW2969738750

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.