ArticleIEEE transactions on medical imaging2020
mDixon-Based Synthetic CT Generation for PET Attenuation Correction on Abdomen and Pelvis Jointly Using Transfer Fuzzy Clustering and Active Learning-Based Classification.
Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 62 citations in OpenAlex.
- Gradient system characterization of a 1.5 T MR-Linac with application to 4D UTE imaging for adaptive MR-guided radiotherapy of lung cancer.Magnetic resonance in medicine · 2025Article
- "Advances in biomarker discovery and diagnostics for alzheimer's disease".Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2025Review
- Rethinking Domain-Specific Pretraining by Supervised or Self-Supervised Learning for Chest Radiograph Classification: A Comparative Study Against ImageNet Counterparts in Cold-Start Active Learning.Health care science · 2025Article
- An active learning approach to train a deep learning algorithm for tumor segmentation from brain MR images.Insights into imaging · 2023Article
- Pelvic PET/MR attenuation correction in the image space using deep learning.Frontiers in oncology · 2023Article
- Abdominopelvic MR to CT registration using a synthetic CT intermediate.Journal of applied clinical medical physics · 2022Article
- Sleep Quality Detection Based on EEG Signals Using Transfer Support Vector Machine Algorithm.Frontiers in neuroscience · 2021Article
- Attenuation correction for human PET/MRI studies.Physics in medicine and biology · 2020Article
- Improved PET/MRI attenuation correction in the pelvic region using a statistical decomposition method on T2-weighted images.EJNMMI physics · 2020Article
- An Intelligent Diagnosis Method of Brain MRI Tumor Segmentation Using Deep Convolutional Neural Network and SVM Algorithm.Computational and mathematical methods in medicine · 2020Article
- Multimodal MRI Brain Tumor Image Segmentation Using Sparse Subspace Clustering Algorithm.Computational and mathematical methods in medicine · 2020Article
- An Epilepsy Detection Method Using Multiview Clustering Algorithm and Deep Features.Computational and mathematical methods in medicine · 2020Article
- Research of Epidemic Big Data Based on Improved Deep Convolutional Neural Network.Computational and mathematical methods in medicine · 2020Article
- Diagnostic and Gradation Model of Osteoporosis Based on Improved Deep U-Net Network.Journal of medical systems · 2019Article
- Segmentation and Diagnosis of Papillary Thyroid Carcinomas Based on Generalized Clustering Algorithm in Ultrasound Elastography.Journal of medical systems · 2019Article
- Transforming UTE-mDixon MR Abdomen-Pelvis Images Into CT by Jointly Leveraging Prior Knowledge and Partial Supervision.IEEE/ACM transactions on computational biology and bioinformaticsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
19 authors at 7 institutions in 3 countries.
Funding
Abstract
We propose a new method for generating synthetic CT images from modified Dixon (mDixon) MR data. The synthetic CT is used for attenuation correction (AC) when reconstructing PET data on abdomen and pelvis. While MR does not intrinsically contain any information about photon attenuation, AC is needed in PET/MR systems in order to be quantitatively accurate and to meet qualification standards required for use in many multi-center trials. Existing MR-based synthetic CT generation methods either use advanced MR sequences that have long acquisition time and limited clinical availability or use matching of the MR images from a newly scanned subject to images in a library of MR-CT pairs which has difficulty in accounting for the diversity of human anatomy especially in patients that have pathologies. To address these deficiencies, we present a five-phase interlinked method that uses mDixon MR acquisition and advanced machine learning methods for synthetic CT generation. Both transfer fuzzy clustering and active learning-based classification (TFC-ALC) are used. The significance of our efforts is fourfold: 1) TFC-ALC is capable of better synthetic CT generation than methods currently in use on the challenging abdomen using only common Dixon-based scanning. 2) TFC partitions MR voxels initially into the four groups regarding fat, bone, air, and soft tissue via transfer learning; ALC can learn insightful classifiers, using as few but informative labeled examples as possible to precisely distinguish bone, air, and soft tissue. Combining them, the TFC-ALC method successfully overcomes the inherent imperfection and potential uncertainty regarding the co-registration between CT and MR images. 3) Compared with existing methods, TFC-ALC features not only preferable synthetic CT generation but also improved parameter robustness, which facilitates its clinical practicability. Applying the proposed approach on mDixon-MR data from ten subjects, the average score of the mean absolute prediction deviation (MAPD) was 89.78±8.76 which is significantly better than the 133.17±9.67 obtained using the all-water (AW) method (p=4.11E-9) and the 104.97±10.03 obtained using the four-cluster-partitioning (FCP, i.e., external-air, internal-air, fat, and soft tissue) method (p=0.002). 4) Experiments in the PET SUV errors of these approaches show that TFC-ALC achieves the highest SUV accuracy and can generally reduce the SUV errors to 5% or less. These experimental results distinctively demonstrate the effectiveness of our proposed TFCALC method for the synthetic CT generation on abdomen and pelvis using only the commonly-available Dixon pulse sequence.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.