ArticleIrish journal of medical science2020
Ureteric stenting with magnetic retrieval: an alternative to traditional methods.
Article in Irish journal of medical science, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 2 syntheses or guidelines pooled it, 17 citations in OpenAlex.
- Pooled it
- A systematic review of magnetic versus conventional ureteric stents for short term ureteric stenting.Irish journal of medical science · 2022Pooled it
- The Function Improved of the Newly Designed Magnetic-End Ureteric Stenting Retrieval Device: A Clinical Prospective Randomized and Control Trial in a Multicenter Study.Contrast media & molecular imaging · 2022Trial
- Striking a balance: outcomes of short-term Mono-J placement following ureterorenoscopy.Urolithiasis · 2021Trial
- MAG-EX study protocol: magnetic stent versus stent on extraction string in patients after ureteroscopy-a multi-centre randomised controlled trial.Translational andrology and urology · 2026Article
- Comparison of Magnetic and Conventional Double-J Stent Following Kidney Transplantation: A Randomized Controlled Trial.Transplantation direct · 2025Article
- Review
- Single-use digital flexible cystoscope for double J removal versus reusable instruments: a prospective, comparative study of functionality, risk of infection, and costs.World journal of urology · 2023Observational
- The "ins and outs" of the magnetic ureteral stent: A novel innovation in Endourology.Current urology · 2023Article
- Comparison of the Removal Efficiency and Safety of Magnetic Versus Conventional Ureteral Stents: A Systematic Review and Meta-analysis.European urology open science · 2023Review
- Beyond the gut: spectrum of magnetic surgery devices.Frontiers in surgery · 2023Review
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionUreteric stents are frequently placed following endo-urological procedures. These stents cause significant morbidity for patients. Standard ureteric stents are removed by flexible cystoscopy. This procedure can be unpleasant for patients and requires additional resources. A newly designed magnetic stent allows removal in an outpatient setting. The aim of our study is to compare the magnetic stent and standard ureteric stents with regard to morbidity, pain on stent removal and cost-effectiveness.
methodsThis study was carried out across two sites between September 2016 and July 2017. In site A, a magnetic stent (Urotech, Black-Star®) is removed by magnetic retrieval device. Fifty consecutive patients completed the validated Ureteric Stent Symptom Questionnaire (USSQ) and visual analogue scale (VAS) at the time of stent removal. On site B, a soft polyurethane stent (Cook Universa) was removed by flexible cystoscopy. Fifty patients were identified retrospectively and completed questionnaires by post. Cost analysis was also performed.
resultsOne hundred questionnaires were included for analysis. No significant difference in stent morbidity as assessed by the USSQ was shown between both groups. Median duration of stenting was significantly shorter in the magnetic stent group (5.5 versus 21.5 days, p < 0.001). Mean pain on stent removal was significantly less with magnetic retrieval (2.9 versus 3.9, p < 0.05). Complication rates were similar in both groups. Cost analysis showed a cost saving of €203 per patient with the magnetic stent group.