Trial reportPloS one2019
Graft glycocalyx degradation in human liver transplantation.
Trial report in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.
- The Effect of Hypothermic Machine Perfusion to Ameliorate Ischemia-Reperfusion Injury in Donor Organs.Frontiers in immunology · 2022Pooled it
- Effect of Normothermic Machine Perfusion on Glycocalyx Shedding During Liver Transplantation - A Prospective Pilot Study.Transplant international : official journal of the European Society for Organ Transplantation · 2026Trial
- Endothelial glycocalyx during early reperfusion in patients undergoing cardiac surgery.PloS one · 2021Trial
- Evaluating the endothelial glycocalyx from bench to bedside: a translational framework for microvascular assessment.Angiogenesis · 2026Review
- Review
- Complement mediated thrombotic microangiopathy after liver transplantation in combination with a novel C6 variant of uncertain significance.Frontiers in immunology · 2026Article
- Static Cold Storage and Machine Perfusion: Redefining the Role of Preservation and Perfusate Solutions.International journal of molecular sciences · 2025Review
- Endothelial Glycocalyx Shedding and Hemodynamic Variables During Hepatic and Pancreatic Resection Surgery.Medicina (Kaunas, Lithuania) · 2025Article
- Glycocalyx kinetics and injury during liver procurement and transplantation as predictors of early graft dysfunction.Frontiers in transplantation · 2025Article
- The Endothelial Glycocalyx in Pig-to-Baboon Cardiac Xenotransplantation-First Insights.Biomedicines · 2024Article
- Loss of Endothelial Glycocalyx During Normothermic Machine Perfusion of Porcine Kidneys Irrespective of Pressure and Hematocrit.Transplantation direct · 2023Article
- Review
- Article
- The Role of IGL-2 Preservation Solution on Rat Livers during SCS and HOPE.International journal of molecular sciences · 2022Article
- Liver Graft Hypothermic Static and Oxygenated Perfusion (HOPE) Strategies: A Mitochondrial Crossroads.International journal of molecular sciences · 2022Review
- Heparanase inhibition preserves the endothelial glycocalyx in lung grafts and improves lung preservation and transplant outcomes.Scientific reports · 2021Article
- The Endothelial Glycocalyx and Organ Preservation-From Physiology to Possible Clinical Implications for Solid Organ Transplantation.International journal of molecular sciences · 2021Review
- High Preoperative Serum Syndecan-1, a Marker of Endothelial Glycocalyx Degradation, and Severe Acute Kidney Injury after Valvular Heart Surgery.Journal of clinical medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveIschaemia/reperfusion-injury degrades endothelial glycocalyx. Graft glycocalyx degradation was studied in human liver transplantation.
methodsTo assess changes within the graft, blood was drawn from portal and hepatic veins in addition to systemic samples in 10 patients. Plasma syndecan-1, heparan sulfate and chondroitin sulfate, were measured with enzyme-linked immunosorbent assay.
resultsDuring reperfusion, syndecan-1 levels were higher in graft caval effluent [3118 (934-6141) ng/ml, P = 0.005] than in portal venous blood [101 (75-121) ng/ml], indicating syndecan-1 release from the graft. Concomitantly, heparan sulfate levels were lower in graft caval effluent [96 (32-129) ng/ml, P = 0.037] than in portal venous blood [112 (98-128) ng/ml], indicating heparan sulfate uptake within the graft. Chondroitin sulfate levels were equal in portal and hepatic venous blood. After reperfusion arterial syndecan-1 levels increased 17-fold (P < 0.001) and heparan sulfate decreased to a third (P < 0.001) towards the end of surgery.
conclusionSyndecan-1 washout from the liver indicates extensive glycocalyx degradation within the graft during reperfusion. Surprisingly, heparan sulfate was taken up by the graft during reperfusion. Corroborating previous experimental reports, this suggests that endogenous heparan sulfate might be utilized within the graft in the repair of damaged glycocalyx.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials