Evidence map›Paper›PMID 31410525›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2020

Small differences in tibial contact locations following kinematically aligned TKA from the native contralateral knee.

Stephanie Nicolet-Petersen, Augustine Saiz, Trevor Shelton, Stephen M Howell, Maury L Hull

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. More AnteriorFrontiers in bioengineering and biotechnology · 2021
    Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stephanie Nicolet-PetersenDepartment of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA.
Augustine SaizDepartment of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA, 95817, USA.
Trevor SheltonDepartment of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA, 95817, USA.
Stephen M HowellDepartment of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA.
Maury L HullDepartment of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA. mlhull@ucdavis.edu.ORCID http://orcid.org/0000-0001-8305-4589

Funding

Zimmer-Biomet IRU2016-101K:Knees
6 · The paper itself

Abstract

purposeKinematically aligned (KA) TKA strives to restore native limb and knee alignments without ligament release with the premise that knee function likewise will be closely restored to native to the extent enabled by the components used. This study determined differences in anterior-posterior (AP) tibial contact locations of a KA TKA performed with asymmetric, fixed bearing, posterior cruciate-retaining (PCR) components from those of the native contralateral knee and also determined the incidence of posterior rim contact of the tibial insert during a deep knee bend and a step-up.

methodsBoth knees were imaged using single-plane fluoroscopy for 25 patients with a calipered KA TKA and a native knee in the contralateral limb. AP tibial contact locations in each compartment were determined following 3D model-to-2D image registration. Differences in mean AP tibial contact locations in each compartment between the KA TKA knees and the native contralateral knees were analysed. Contact locations either on or beyond the most posterior point of the tibial insert determined the occurrence of posterior rim contact.

resultsMean AP tibial contact locations for both native and KA TKA knees remained relatively centred in the medial compartment but moved posterior in the lateral compartment during flexion. In both the medial and lateral compartments, differences in mean AP tibial contact locations between the KA TKA knees and the native contralateral knees were more posterior and greatest at 0° flexion for both activities (4 mm, p = 0.0009 and 7 mm, p < 0.0001 for deep knee bend and 6 mm, p < 0.0001 and 8 mm, p < 0.0001 for step-up in the medial and lateral compartments, respectively). The incidence of posterior rim contact of the tibial insert was 16% (4 of 25 patients) but the lowest Oxford Knee Score was 43 for these patients. The median Oxford Knee Score for all patients was 46 (out of 48).

conclusionsCalipered KA TKA with asymmetric, fixed bearing, PCR components resulted in mean AP tibial contact locations which were relatively centred in the compartments and differed at most from those of the native contralateral knee by approximately 15% of the AP dimension of a mid-sized tibial baseplate. Although posterior rim contact occurred in some patients, all such patients had high patient-reported outcome scores. LEVEL OF EVIDENCE: Therapeutic, Level III.

Indexed as

Knee ProsthesisRange of Motion, ArticularAgedAged, 80 and overArthroplasty, Replacement, KneeBiomechanical PhenomenaFemaleHumansJoint InstabilityKnee JointMaleMiddle AgedPatient Reported Outcome MeasuresTibiaActivities of daily livingContact kinematicsDeep knee bendKinematic alignmentPosterior edge loadingStep-upTibiofemoral jointTotal knee arthroplastyTotal knee replacement

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.