ArticleBMC ophthalmology2019
Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation.
Article in BMC ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed.
- Comparison of measurements of anterior chamber angleWorld journal of clinical cases · 2020Trial
- Quantitative Ciliary Body Imaging Using Image-Registered Swept-Source AS-OCT and Ultrasound Biomicroscopy.Translational vision science & technology · 2026Article
- Automatic measurement and evaluation of anterior segment anatomical structures via UBM images using a deep learning-based approach.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026Article
- Comparison of three different instruments for vault measurements after implantable collamer lens implantation.International journal of ophthalmology · 2026Article
- Rapid evaluation of vault post-ICL surgery using digital slit lamp microscope photography.BMC ophthalmology · 2025Article
- Clinical Applications of Anterior Segment Optical Coherence Tomography in Managing Phakic and Secondary Intraocular Lens Implants: A Comprehensive Review.Diagnostics (Basel, Switzerland) · 2025Review
- Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation.Clinical optometry · 2025Article
- Analysis of surgically induced astigmatism of the anterior, posterior, and total cornea after implantable collamer lens implantation: a comparative study between temporal and superior clear corneal incisions.BMC ophthalmology · 2024Article
- Repeatability and Agreement of Central Vault for Implantable Collamer Lens Obtained by the Tomey OA-2000 Biometer and Spectralis OCT.Journal of ophthalmology · 2024Article
- Bibliometric and visualized analysis of posterior chamber phakic intraocular lens research between 2003 and 2023.Frontiers in medicine · 2024Review
- Diagnostic Techniques to Increase the Safety of Phakic Intraocular Lenses.Diagnostics (Basel, Switzerland) · 2023Review
- Evaluation of Multimodal Biometric Parameters for Diagnosing Acute Angle Closure Secondary to Lens Subluxation.Ophthalmology and therapy · 2023Article
- Development of an implantable collamer lens sizing model: a retrospective study using ANTERION swept-source optical coherence tomography and a literature review.BMC ophthalmology · 2023Review
- A quantitative study of the effect of ICL orientation selection on post-operative vault and model-assisted vault prediction.Frontiers in neurology · 2023Article
- Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis.BMC ophthalmology · 2022Article
- Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes.International ophthalmology · 2022Observational
- Comparison of Vault Measurements Using a Swept-Source OCT-Based Optical Biometer and Anterior Segment OCT.Frontiers in medicine · 2022Article
- Distribution of White-to-White Corneal Diameter and Anterior Chamber Depth in Chinese Myopic Patients.Frontiers in medicine · 2021Article
- Ocular Manifestations of Acute Secondary Angle Closure Associated With Lens Subluxation.Frontiers in medicine · 2021Article
- Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens.Scientific reports · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundTo compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM).
methodsAnterior chamber depth (ACD), distance between corneal endothelium and anterior surface of ICL(C-ICL) and central vault were measured in 82 phakic myopic eyes of 82 patients who underwent ICL surgery, by using AS-OCT, Pentacam and UBM consecutively at 3 months follow up. The correlation and agreement of instruments were accessed by using Intraclass correlation coefficient (ICC) and the Bland-Altman plot.
resultsAS-OCT showed higher ACD, C -ICL and central vault measurements than both of Pentacam and UBM (P < 0.001), while Pentacam showed lower measurements than UBM (P < 0.05). The Pearson correlation coefficient (r) was 0.91 to 0.96, and ICC was 0.95 to 0.98 for all measurements between difference devices (all P < 0.001). The 95% limits of agreement of ACD, C-ICL, vault measurements were 0.13 to 0.38 mm, - 0.07 to 0.27 mm, 0.08 to 0.34 mm between AS-OCT and Pentacam, - 0.03 to 0.33 mm, - 0.16 to 0.31 mm, - 0.10 to 0.26 mm between AS-OCT and UBM, and - 0.29 to 0.07 mm, - 0.25 to 0.20 mm, - 0.31 to 0.05 mm between Pentacam and UBM, respectively.
conclusionsAS-OCT demonstrated significantly higher value, while Pentacam demonstrated significantly lower value than UBM for ACD, C-ICL and central vault measurements in myopic eyes after ICL surgery. Measurements with these instruments were highly correlated, but could not replace each other especially for vault. This study provided valuable information about how to judge the results of anterior segment parameters of eyes implanted with ICL V4c from different devices.
trial registrationRegistration number: ChiCTR-OOC-16008987 . Retrospectively registered: 08 August 2016.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.