ArticleSensors (Basel, Switzerland)2019
Thermal Drift Investigation of an SOI-Based MEMS Capacitive Sensor with an Asymmetric Structure.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Self-Calibration Technique with Lightweight Algorithm for Thermal Drift Compensation in MEMS Accelerometers.Micromachines · 2022Article
- Lightweight Thermal Compensation Technique for MEMS Capacitive Accelerometer Oriented to Quasi-Static Measurements.Sensors (Basel, Switzerland) · 2021Article
- Research on High-Resolution Miniaturized MEMS Accelerometer Interface ASIC.Sensors (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
High-precision, low-temperature-sensitive microelectromechanical system (MEMS) capacitive accelerometers are widely used in aerospace, automotive, and navigation systems. An analytical study of the temperature drift of bias (TDB) and temperature drift of scale factor (TDSF) for an asymmetric comb capacitive accelerometer is presented in this paper. A five-layer model is established for the equivalent expansion ratio in the TDB and TDSF formulas, and the results calculated by the weighted average of thickness and elasticity modulus method are closest to the results of the numerical simulation. The analytical formulas of TDB and TDSF for an asymmetric structure are obtained. For an asymmetric structure, TDB is only related to thermal deformation and fabrication error. Additionally, half of the fixed electrode distance is not included in the expressions of Δ d and Δ D for asymmetric structures, thus resulting in the TDSF of the asymmetric structure being smaller compared to a symmetric structure with the same structural parameters. The TDSF of the symmetric structure is [-200.2 ppm/°C, -261.6 ppm/°C], while the results of the asymmetric structure are [-11.004 ppm/°C, -72.404 ppm/°C] under the same set of parameters. The parameters of the optimal asymmetric structure are obtained for fabrication guidance using numerical methods. In the experiment, the TDSF and TDB of the packaged structure and the non-packaged structure are compared, and a significant effect of the package on the signal output is found. The TDB is reduced from 3000 to 60 μg/°C, while the TDSF is reduced from 3000 to 140 ppm/°C.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.