ArticleMedical physics2019

A new iterative algorithm for ring artifact reduction in CT using ring total variation.

Morteza Salehjahromi, Qian Wang, Yanbo Zhang, Lars A Gjesteby, Dan Harrison, Ge Wang, Peter M Edic, Hengyong Yu

Abstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Morteza SalehjahromiDepartment of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, 01854, USA.
Qian WangDepartment of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, 01854, USA.
Yanbo ZhangPing An Technology, U.S. Research Lab, Palo Alto, CA, 94306, USA.
Lars A GjestebyDepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180, USA.
Dan HarrisonDepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180, USA.
Ge WangDepartment of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180, USA.
Peter M EdicGE Research, Niskayuna, NY, 12309, USA.
Hengyong YuDepartment of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, 01854, USA.

Funding

High dose efficiency CT SystemU01EB017140 · NIBIB · STANFORD UNIVERSITY · PI EDIC, PETER, PELC, NORBERT J. · 2014 to 2018
$5.4M
NIBIB NIH HHS U01 EB017140NIH/NIBIB U01 EB017140
6 · The paper itself

Abstract

purposeIn computed tomography (CT), miscalibrated or imperfect detector elements produce stripe artifacts in the sinogram. The stripe artifacts in Radon space are responsible for concentric ring artifacts in the reconstructed images. In this work, a novel optimization model is proposed to remove the ring artifacts in an iterative reconstruction procedure.

methodIn the proposed optimization model, a novel ring total variation (RTV) regularization is developed to penalize the ring artifacts in the image domain. Moreover, to correct the sinogram, a new correcting vector is proposed to compensate for malfunctioning of detectors in the projection domain. The optimization problem is solved by using the alternating minimization scheme (AMS). In each iteration, the fidelity term along with the RTV regularization is solved using the alternating direction method of multipliers (ADMM) to find the image, and then the correcting coefficient vector is updated for certain detectors according to the obtained image. Because the sinogram and the image are simultaneously updated, the proposed method basically performs in both image and sinogram domains.

resultsThe proposed method is evaluated using both simulated and physical phantom datasets containing different ring artifact patterns. In the simulated datasets, the Shepp-Logan phantom, a real chest scan image and a noisy low-contrast phantom are considered for the performance evaluation of our method. We compare the quantitative root mean square error (RMSE) and structural similarity (SSIM) results of our algorithm with wavelet-Fourier sinogram filtering method by Munch et al., the ring artifact reduction method by Brun et al., and the TV-based ring correction method by Paleo and Mirone. Our proposed method is also evaluated using a physical phantom dataset where strong ring artifacts are manifest due to the miscalibration of a large number of detectors. Our proposed method outperforms the competing methods in terms of both qualitative and quantitative evaluation results.

conclusionThe experimental results in both simulated and physical phantom datasets show that the proposed method achieves the state-of-the-art ring artifact reduction performance in terms of RMSE, SSIM, and subjective visual quality.

Indexed as

AlgorithmsArtifactsTomography, X-Ray ComputedFourier AnalysisImage Processing, Computer-AssistedPhantoms, Imagingalternating direction method of multipliersalternating minimization schemecomputed tomographyiterative reconstructionring artifactring total variation

Identifiers

PMID31408539
PMCPMC7393670

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.