Oscillometry in Chronic Obstructive Lung Disease: In vitro and in vivo evaluation of the impulse oscillometry and tremoflo devices.

Lennart K A Lundblad, Ruzica Miletic, Eeva Piitulainen, Per Wollmer

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 27 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Oscillometry of the respiratory system: a translational opportunity not to be missed.American journal of physiology. Lung cellular and molecular physiology · 2021
    Review
  11. Lung function monitoring in the era of respiratory pandemics.Clinical physiology and functional imaging · 2020
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Lennart K A LundbladMeakins-Christie Laboratories, McGill University, Montréal, QC, Canada. lennart.lundblad@mcgill.ca.
Ruzica MileticDepartment of Biomedical Science, Malmö University, Malmö, Sweden.
Eeva PiitulainenDepartment of Respiratory Medicine and Allergology, Lund University, Malmö, Sweden.
Per WollmerDepartment of Translational Medicine, Lund University, Malmö, Sweden.
Lund University · SEChristie (Canada) · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Impedance, or oscillometry, measurements of the respiratory system can generate information about the function of the respiratory system not possible with traditional spirometry. There are currently several instruments on the market using different perturbations. We have compared a new respiratory oscillometry instrument, the tremoflo, with Impulse Oscillometry (IOS). Patients with a physician's diagnosis of chronic obstructive lung disease (COPD) and healthy subjects were recruited. They underwent assessment of respiratory function with oscillometry using the IOS and tremoflo devices and the resulting impedance data from the two methods were compared. The two devices were also tested against a reference respiratory phantom with variable resistances. Whereas both devices detected impairments in the patients' lung function commensurate with small airways pathology, the tremoflo appeared to be more sensitive than the IOS. We found systematic differences between the two instruments especially for reactance measurements where the area over the reactance curve (AX) was significantly lower with the IOS compared with the tremoflo (p < 0.001). Moreover, the agreement between the two devices was reduced with increasing severity of the disease as determined with a Bland-Altman test. Testing both instruments against a respiratory phantom unit confirmed that the resistance measured by the tremoflo compares closely with the known resistance of test loads, whereas the IOS' resistance correlated with a test load of 0.19, kPa.s.L

Indexed as

AdultFemaleHumansMaleMiddle AgedOscillometryPulmonary Disease, Chronic ObstructiveRespiratory Function Tests

Identifiers

PMID31406190
PMCPMC6690921
OpenAlexW2967832518

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.