Evidence map›Paper›PMID 31403409›Full record

ArticleIEEE transactions on medical imaging2020

Simultaneous Multi-VENC and Simultaneous Multi-Slice Phase Contrast Magnetic Resonance Imaging.

Suhyung Park, Liyong Chen, Jennifer Townsend, Hyunyeol Lee, David A Feinberg

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Suhyung Park
Liyong Chen
Jennifer Townsend
Hyunyeol Lee
David A Feinberg

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
Foundations of MRI Corticography for mesoscale organization and neuronal circuitryR01MH111444 · NIMH · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN · 2016 to 2020
$5.1M
Highly Accelerated Simultaneous Multi-Slice Phase Contrast MRIR44MH112210 · NIMH · ADVANCED MRI TECHNOLOGY, LLC · PI FEINBERG, DAVID ALAN · 2016 to 2017
$2.7M
HIGHLY EFFICIENT CEREBRAL PERFUSION MRIR44NS084788 · NINDS · ADVANCED MRI TECHNOLOGY, LLC · PI FEINBERG, DAVID ALAN · 2013 to 2017
$2.5M
NIBIB NIH HHS U01 EB025162NIMH NIH HHS R01 MH111444NIMH NIH HHS R44 MH112210NINDS NIH HHS R44 NS084788
6 · The paper itself

Abstract

This work develops a novel, simultaneous multi-VENC and simultaneous multi-slice (SMV+SMS) imaging in a single acquisition for robust phase contrast (PC) MRI. To this end, the pulse sequence was designed to permit concurrent acquisition of multiple VENCs as well as multiple slices on a shared frequency encoding gradient, in which each effective echo time for multiple VENCs was controlled by adjusting net gradient area while multiple slices were simultaneously excited by employing multiband resonance frequency (RF) pulses. For VENC and slice separation, RF phase cycling and gradient blip were applied to create both inter-VENC and inter-slice shifts along phase encoding direction, respectively. With an alternating RF phase cycling that generates oscillating steady-state with low and high signal amplitude, the acquired multi-VENC k-space was reformulated into 3D undersampled k-space by generating a virtual dimension along VENC direction for modulation induced artifact reduction. In vivo studies were conducted to validate the feasibility of the proposed method in comparison with conventional PC MRI. The proposed method shows comparable performance to the conventional method in delineating both low and high flow velocities across cardiac phases with high spatial coverage without apparent artifacts. In the presence of high flow velocity that is above the VENC value, the proposed method exhibits clear depiction of flow signals over conventional method, thereby leading to high VNR image with improved velocity dynamic range.

Indexed as

Blood Flow VelocityArtifactsBlood CirculationHumansImage Processing, Computer-AssistedMagnetic Resonance Imaging

Identifiers

PMID31403409
PMCPMC7138512

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.