Evidence map›Paper›PMID 31403212›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2019

Meniscal Replacement With a Silk Fibroin Scaffold Reduces Contact Stresses in the Human Knee.

Svenja Stein, Sabrina Höse, Daniela Warnecke, Cristina Gentilini, Nick Skaer, Robert Walker, Oliver Kessler, Anita Ignatius, Lutz Dürselen

Open access · hybridAbstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. In Pursuit of Quantifying Patient Knee Contact Mechanics: Finite Element Model Validation of Cadaveric Knees in Axially Loaded MRI Scans.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
  3. Impact of hyaluronic acid injection on the knee joint friction.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023
    Article
  4. Autologous semitendinosus tendon graft could function as a meniscal transplant.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022
    Article
  5. Article
  6. Natural biopolymer scaffold for meniscus tissue engineering.Frontiers in bioengineering and biotechnology · 2022
    Review
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Svenja SteinInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.ORCID 0000-0003-0874-8577
Sabrina HöseInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.
Daniela WarneckeInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.
Cristina GentiliniOrthox Ltd., 66 Innovation Drive, Milton Park, Abingdon, OX14 4RQ, United Kingdom.
Nick SkaerOrthox Ltd., 66 Innovation Drive, Milton Park, Abingdon, OX14 4RQ, United Kingdom.
Robert WalkerOrthox Ltd., 66 Innovation Drive, Milton Park, Abingdon, OX14 4RQ, United Kingdom.
Oliver KesslerCentre of Orthopaedics and Sports (affiliated to Orthopaedic University Hospital, Leipziger Straße 44, 39120 Magdeburg, Germany), Albisriederstraße 243A, 8047, Zurich, Switzerland.
Anita IgnatiusInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.ORCID 0000-0002-4782-1979
Lutz DürselenInstitute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Helmholtzstraße 14, 89081, Ulm, Germany.ORCID 0000-0002-5470-5423
Helmholtz-Institute Ulm · DEOrthox (United Kingdom) · GBUniversity Hospital Leipzig · DE

Funding

German Armed Forces E/U2AD/ED001/EF551National Institute for Health Research - Invention for Innovation (i4i) II-LB-0417-20005Wellcome TrustWellcome Trust 100917/z/13/z
6 · The paper itself

Abstract

The aim of the current study was to verify if a previously developed silk fibroin scaffold for meniscal replacement is able to restore the physiological distribution of contact pressure (CP) over the articulating surfaces in the human knee joint, thereby reducing peak loads occurring after partial meniscectomy. The pressure distribution on the medial tibial articular surface of seven human cadaveric knee joints was analysed under continuous flexion-extension movements and under physiological loads up to 2,500 N at different flexion angles. Contact area (CA), maximum tibiofemoral CP, maximum pressure under the meniscus and the pressure distribution were analysed for the intact meniscus, after partial meniscectomy as well as after partial medial meniscal replacement using the silk fibroin scaffold. Implantation of the silk fibroin scaffold considerably improved tibiofemoral contact mechanics after partial medial meniscectomy. While the reduced CA after meniscectomy was not fully restored by the silk fibroin scaffold, clinically relevant peak pressures on the articular cartilage surface occurring after partial meniscectomy were significantly reduced. Nevertheless, at high flexion angles static testing demonstrated that normal pressure distribution comparable to the intact meniscus could not be fully achieved. The current study demonstrates that the silk fibroin implant possesses attributes that significantly improve tibiofemoral CPs within the knee joint following partial meniscectomy. However, the failure to fully recapitulate the CAs and pressures observed in the intact meniscus, particularly at high flexion angles, indicates that the implant's biomechanical properties may require further improvement to completely restore tibiofemoral contact mechanics. © 2019 The Authors. Journal of Orthopaedic Research

Indexed as

Tissue ScaffoldsFemurFibroinsHumansMenisci, TibialPressureStress, MechanicalTibiaFibroinsknee joint degenerationmeniscus injurymeniscus replacementsilk fibroin scaffoldtibiofemoral contact mechanics

Identifiers

PMID31403212
PMCPMC8647912
OpenAlexW2968710592

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.