ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2019
Meniscal Replacement With a Silk Fibroin Scaffold Reduces Contact Stresses in the Human Knee.
Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 19 citations in OpenAlex.
- Full-flexion gap balancing-driven personalized preoperative planning for TKA: biomechanical evidence of improved load symmetry in an in vitro model.Arthroplasty (London, England) · 2026Article
- In Pursuit of Quantifying Patient Knee Contact Mechanics: Finite Element Model Validation of Cadaveric Knees in Axially Loaded MRI Scans.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025Article
- Impact of hyaluronic acid injection on the knee joint friction.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Autologous semitendinosus tendon graft could function as a meniscal transplant.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Article
- Demineralized Cortical Bone Matrix Augmented With Peripheral Blood-Derived Mesenchymal Stem Cells for Rabbit Medial Meniscal Reconstruction.Frontiers in bioengineering and biotechnology · 2022Article
- Natural biopolymer scaffold for meniscus tissue engineering.Frontiers in bioengineering and biotechnology · 2022Review
- Influence of Menisci on Tibiofemoral Contact Mechanics in Human Knees: A Systematic Review.Frontiers in bioengineering and biotechnology · 2021Review
- Development of a Pressure-Sensitive Conductive Rubber Sensor for Analyzing Meniscal Injury in Porcine Models.Applied bionics and biomechanics · 2021Article
- Clinical application of polyurethane meniscal scaffold: A meta-analysis.Journal of orthopaedicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
Abstract
The aim of the current study was to verify if a previously developed silk fibroin scaffold for meniscal replacement is able to restore the physiological distribution of contact pressure (CP) over the articulating surfaces in the human knee joint, thereby reducing peak loads occurring after partial meniscectomy. The pressure distribution on the medial tibial articular surface of seven human cadaveric knee joints was analysed under continuous flexion-extension movements and under physiological loads up to 2,500 N at different flexion angles. Contact area (CA), maximum tibiofemoral CP, maximum pressure under the meniscus and the pressure distribution were analysed for the intact meniscus, after partial meniscectomy as well as after partial medial meniscal replacement using the silk fibroin scaffold. Implantation of the silk fibroin scaffold considerably improved tibiofemoral contact mechanics after partial medial meniscectomy. While the reduced CA after meniscectomy was not fully restored by the silk fibroin scaffold, clinically relevant peak pressures on the articular cartilage surface occurring after partial meniscectomy were significantly reduced. Nevertheless, at high flexion angles static testing demonstrated that normal pressure distribution comparable to the intact meniscus could not be fully achieved. The current study demonstrates that the silk fibroin implant possesses attributes that significantly improve tibiofemoral CPs within the knee joint following partial meniscectomy. However, the failure to fully recapitulate the CAs and pressures observed in the intact meniscus, particularly at high flexion angles, indicates that the implant's biomechanical properties may require further improvement to completely restore tibiofemoral contact mechanics. © 2019 The Authors. Journal of Orthopaedic Research
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.