Radiotherapy of patients with cardiac implantable electronic devices according to the DEGRO/DGK guideline-is the risk of relevant errors overestimated?
Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 2 syntheses or guidelines pooled it, 10 citations in OpenAlex.
- Technical aspects of SBRT for therapy-refractory ventricular tachycardia: a systematic review for radiation oncologists.Radiation oncology (London, England) · 2025Pooled it
- A systematic review and meta-analysis on oncological radiotherapy in patients with a cardiac implantable electronic device: Prevalence and predictors of device malfunction in 3121 patients.European journal of clinical investigation · 2023Pooled it
- Dosimetric feasibility of stereotactic arrhythmia radioablation for ventricular tachycardia in patients with a subcutaneous implantable cardioverter defibrillator.Physics and imaging in radiation oncology · 2025Article
- Local dose rate effects in implantable cardioverter-defibrillators with flattening filter free and flattened photon radiation.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2022Article
- Radiotherapy is safe in patients with implantable cardiac devices. Analysis of a systematic interrogation follow-up.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2020Article
- Radiosurgery for ventricular tachycardia: preclinical and clinical evidence and study design for a German multi-center multi-platform feasibility trial (RAVENTA).Clinical research in cardiology : official journal of the German Cardiac Society · 2020Article
- Stereotactic body radiotherapy for ventricular tachycardia (cardiac radiosurgery) : First-in-patient treatment in Germany.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIonizing radiation is able to cause severe damage to cardiac implantable electronic devices (CIED). In Germany, the DEGRO/DGK guideline recommends close monitoring of patients with CIEDs undergoing radiotherapy (RT). Nevertheless, especially in the era of intensity-modulated techniques and predominant use of 6 MV photons, errors of CIEDs are rare events. Therefore, we performed daily CIED controls and hypothesized that no relevant device interaction would occur in our cohort.
methodsFrom 2014 to 2018, we collected data of 51 patients (62 courses) with daily interrogation (n = 1046) of CIED. The dose to the skin above the CIED was measured by semiconductor or ion chamber dosimetry at least once per RT course. In many cases the dose was also calculated.
resultsThe prescribed dose to the planning target volume (PTV) ranged from 7.5 to 78.0 Gy (IQR 27.8-61.0 Gy). The median measured cumulative dose to the skin above the CIED was 0.17 Gy, whereas the median calculated dose was 1.03 Gy. No error occurred in the group with maximum beam energy >10 MeV. Three events without clinical relevance could be recognized in the group with an intensity-modulated technique at 6 MV. None of the three concerned devices were located directly within the PTV.
conclusionErrors of CIEDs during RT are rare events. The approach according to the DEGRO/DGK guideline is safe, but also consumes resources. In our cohort it was not compulsory to relocate any CIED. Clinically relevant events are uncommon, so it remains debatable which procedure is necessary. Daily controls could be avoided in some selected cases without compromising patient safety.