Evidence map›Paper›PMID 31399773›Full record

Trial reportThe European journal of health economics : HEPAC : health economics in prevention and care2019

Cost differences between digital tomosynthesis and standard digital mammography in a breast cancer screening programme: results from the To-Be trial in Norway.

Tron Anders Moger, Jayson O Swanson, Åsne Sørlien Holen, Berit Hanestad, Solveig Hofvind

Registry-linked trialAbstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in The European journal of health economics : HEPAC : health economics in prevention and care, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02835625 (Digital Breast Tomosynthesis - The Future Screening Tool for Breast Cancer?), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02835625 nacompletednot on this map

Digital Breast Tomosynthesis - The Future Screening Tool for Breast Cancer?

TypeinterventionalSponsorNorwegian Institute of Public HealthRan2016 to 2021Enrolled29,453ConditionsBreast NeoplasmsArmsSynthetic Mammography + Digital Breast Tomosynthesis, Digital mammography
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. A Review of Breast Imaging for Timely Diagnosis of Disease.International journal of environmental research and public health · 2021
    Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tron Anders MogerDepartment of Health Management and Health Economics, Institute of Health and Society, University of Oslo, Oslo, Norway. tronmo@medisin.uio.no.ORCID http://orcid.org/0000-0003-2865-4762
Jayson O SwansonDepartment of Health Management and Health Economics, Institute of Health and Society, University of Oslo, Oslo, Norway.
Åsne Sørlien HolenCancer Registry of Norway, Oslo, Norway.
Berit HanestadHaukeland University Hospital, Bergen, Norway.
Solveig HofvindCancer Registry of Norway, Oslo, Norway.

Funding

Norges Forskningsråd 247941/H10
6 · The paper itself

Abstract

backgroundSeveral studies in Europe and the US have shown promising results favouring digital breast tomosynthesis compared to standard digital mammography (DM). However, the costs of implementing the technology in screening programmes are not yet known.

methodsA randomised controlled trial comparing the results from digital breast tomosynthesis including synthetic mammograms (DBT) vs. DM was performed in Bergen during 2016 and 2017 as a part of BreastScreen Norway. The trial included 29,453 women and allowed for a detailed comparison of procedure use and screening, recall and treatment costs estimated at the individual level.

resultsThe increased cost of equipment, examination and reading time with DBT vs. DM was €8.5 per screened woman (95% CI 8.4-8.6). Costs of DBT remained significantly higher after adding recall assessment costs, €6.2 (95% CI 4.6-7.9). Substantial reductions in either examination and reading times, price of DBT equipment or price of IT storage and connectivity did not change the conclusion. Adding treatment costs resulted in too wide confidence intervals to draw definitive conclusions (additional costs of tomosynthesis €9.8, 95% CI -56 to 74). Performing biopsy at recall, radiation therapy and chemotherapy was significantly more frequent among women screened with DBT.

conclusionThe results showed lower incremental costs of DBT vs. DM, compared to what is found in previous cost analyses of DBT and DM. However, the incremental costs were still higher for DBT compared with DM after including recall costs. Further studies with long-term treatment data are needed to understand the complete costs of implementing DBT in screening.

Indexed as

Health Care CostsAgedBreast NeoplasmsCost-Benefit AnalysisEarly Detection of CancerFemaleHumansMammographyMiddle AgedNorwayBreast cancerCostsMammographyScreeningTomosynthesis

Identifiers

PMID31399773
PMCPMC6803617

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials