Trial reportThe European journal of health economics : HEPAC : health economics in prevention and care2019
Cost differences between digital tomosynthesis and standard digital mammography in a breast cancer screening programme: results from the To-Be trial in Norway.
Trial report in The European journal of health economics : HEPAC : health economics in prevention and care, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02835625 (Digital Breast Tomosynthesis - The Future Screening Tool for Breast Cancer?), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Digital Breast Tomosynthesis - The Future Screening Tool for Breast Cancer?
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Methodological quality of network meta-analyses of Chinese herbal medicine could be improved: an evidence mapping.Naunyn-Schmiedeberg's archives of pharmacology · 2026Pooled it
- Workload reduction of digital breast tomosynthesis screening using artificial intelligence and synthetic mammography: a simulation study.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Challenges when comparing tomosynthesis and 2D mammography in breast cancer screening.European radiology · 2025Article
- Budget impact analysis of introducing digital breast tomosynthesis in breast cancer screening in Italy.La Radiologia medica · 2024Article
- Breast cancer screening with digital breast tomosynthesis: comparison of different reading strategies implementing artificial intelligence.European radiology · 2023Article
- Personalized breast cancer screening with selective addition of digital breast tomosynthesis through artificial intelligence.Journal of medical imaging (Bellingham, Wash.) · 2023Article
- Costs and Effects of Implementing Digital Tomosynthesis in a Population-Based Breast Cancer Screening Program: Predictions Using Results from the To-Be Trial in Norway.PharmacoEconomics - open · 2022Article
- A Review of Breast Imaging for Timely Diagnosis of Disease.International journal of environmental research and public health · 2021Review
- The cost-effectiveness of digital breast tomosynthesis in a population breast cancer screening program.European radiology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundSeveral studies in Europe and the US have shown promising results favouring digital breast tomosynthesis compared to standard digital mammography (DM). However, the costs of implementing the technology in screening programmes are not yet known.
methodsA randomised controlled trial comparing the results from digital breast tomosynthesis including synthetic mammograms (DBT) vs. DM was performed in Bergen during 2016 and 2017 as a part of BreastScreen Norway. The trial included 29,453 women and allowed for a detailed comparison of procedure use and screening, recall and treatment costs estimated at the individual level.
resultsThe increased cost of equipment, examination and reading time with DBT vs. DM was €8.5 per screened woman (95% CI 8.4-8.6). Costs of DBT remained significantly higher after adding recall assessment costs, €6.2 (95% CI 4.6-7.9). Substantial reductions in either examination and reading times, price of DBT equipment or price of IT storage and connectivity did not change the conclusion. Adding treatment costs resulted in too wide confidence intervals to draw definitive conclusions (additional costs of tomosynthesis €9.8, 95% CI -56 to 74). Performing biopsy at recall, radiation therapy and chemotherapy was significantly more frequent among women screened with DBT.
conclusionThe results showed lower incremental costs of DBT vs. DM, compared to what is found in previous cost analyses of DBT and DM. However, the incremental costs were still higher for DBT compared with DM after including recall costs. Further studies with long-term treatment data are needed to understand the complete costs of implementing DBT in screening.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials