ArticleRadiation oncology (London, England)2019
A treatment planning study comparing IMRT techniques and cyber knife for stereotactic body radiotherapy of low-risk prostate carcinoma.
Article in Radiation oncology (London, England), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Hydraulic endorectal actuator for prostate radiotherapy reduces variations in motion in a silicone rectal phantom.Frontiers in oncology · 2026Article
- Evaluating dosimetric outcomes: a comparison of CyberKnife, VMAT FFF, and Helical Tomotherapy Radixact for treating localized prostate cancer.La Radiologia medica · 2025Article
- Stereotactic Radiosurgery in Metastatic Spine Disease-A Systemic Review of the Literature.Cancers · 2024Review
- Comparative Study of Eclipse and RayStation Multi-Criteria Optimization-Based Prostate Radiotherapy Treatment Planning Quality.Diagnostics (Basel, Switzerland) · 2024Article
- Association between gut microbial change and acute gastrointestinal toxicity in patients with prostate cancer receiving definitive radiation therapy.Cancer medicine · 2023Article
- Cyberknife Radiosurgery for Prostate Cancer after Abdominoperineal Resection (CYRANO): The Combined Computer Tomography and Electromagnetic Navigation Guided Transperineal Fiducial Markers Implantation Technique.Current oncology (Toronto, Ont.) · 2023Article
- Effectiveness of robust optimization against geometric uncertainties in TomoHelical planning for prostate cancer.Journal of applied clinical medical physics · 2023Article
- Stereotactic body radiation therapy for prostate cancer: a study comparing 3-year genitourinary toxicity between CyberKnife and volumetric-modulated arc therapy by propensity score analysis.Radiation oncology (London, England) · 2023Article
- SBRT for Localized Prostate Cancer: CyberKnife vs. VMAT-FFF, a Dosimetric Study.Life (Basel, Switzerland) · 2022Article
- Article
- Adaptive radiation therapy strategies in the treatment of prostate cancer patients using hypofractionated VMAT.Journal of applied clinical medical physics · 2021Article
- Practical considerations for prostate hypofractionation in the developing world.Nature reviews. Urology · 2021Review
- Plan comparison of prostate stereotactic radiotherapy in spacer implant patients.Journal of applied clinical medical physics · 2021Article
- Development of raster scanning IMRT using a robotic radiosurgery system.Journal of radiation research · 2021Article
- Prostate SBRT using O-Ring Halcyon Linac - Plan quality, delivery efficiency, and accuracy.Journal of applied clinical medical physics · 2021Article
- Cyberknife, Helical Tomotherapy and Rapid Arc SIB-SBRT Treatment Plan Comparison for Carcinoma Prostate.Asian Pacific journal of cancer prevention : APJCP · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeComparing radiation treatment plans by using the same safety margins and dose objectives for all techniques, to ascertain the optimal radiation technique for the stereotactic body radiotherapy (SBRT) of low-risk prostate cancer. MATERIAL AND
methodsTreatment plans for 27 randomly selected patients were compared using intensity-modulated (IMRT) techniques as Sliding Window (SW), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT), as well as Cyber Knife (CK) system. The target dose was calculated to 36.25 Gy delivered in five fractions over 1 week. Dosimetric indices for target volume and organs at risk (OAR) as well as normal tissue complication probability (NTCP) of late rectal and urinary bladder toxicities were analyzed.
resultsThe CK provided lower homogeneity in the target volume, but higher values for most of the conformity indices compared to the IMRT approaches. The SW demonstrated superior rectum sparing at medium-to-high dose range (V18 Gy - V32.6 Gy) compared to other techniques (p < 0.05). The whole urinary bladder experienced the best shielding by SW and VMAT at the medium dose (V18 Gy, p < 0.05 versus CK), however we obtained no relevant differences between techniques at the high dose. Generally, the CK demonstrated significantly superior rectum and bladder exposure at V18 Gy as compared to HT, SW, and VMAT. For the rectum, mean NTCP values were significantly superior for HT (NTCP = 2.3%, p < 0.05), and for urinary bladder, the NTCP showed no significant advantages for any technique.
conclusionNo absolute dosimetric advantage was revealed to choose between CK or IMRT techniques for the SBRT of low-grade prostate cancer. Using the same safety margins and dose objectives, IMRT techniques demonstrated superior sparing of the rectum and bladder at a medium dose compared to CK. Comparing different IMRT approaches SW displayed superior rectum sparing at a medium-to-high dose range, whereas both SW and RA revealed superior bladder sparing compared to HT. HT demonstrated a significantly lower NTCP outcome compared to CK or IMRT techniques regarding the rectum. Radiation plans can be optimized further by an individual modification of dose objectives independent of the treatment plan strategy.