Evidence map›Paper›PMID 31398948›Full record

ArticleSensors (Basel, Switzerland)2019

Real-Time Cardiac Beat Detection and Heart Rate Monitoring from Combined Seismocardiography and Gyrocardiography.

Yannick D'Mello, James Skoric, Shicheng Xu, Philip J R Roche, Michel Lortie, Stephane Gagnon, David V Plant

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. A Flexible PVDF Sensor for Forcecardiography.Sensors (Basel, Switzerland) · 2025
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. A Wavelet-Based Approach for Motion Artifact Reduction in Ambulatory Seismocardiography.IEEE journal of translational engineering in health and medicine · 2024
    Article
  14. Cardiac function and posttraumatic stress disorder: a review of the literature and case report.Health promotion and chronic disease prevention in Canada : research, policy and practice · 2023
    Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yannick D'MelloDepartment of Electrical and Computer Engineering, McGill University, Montreal, QC H3A 2T5, Canada. yannick.dmello@mail.mcgill.ca.
James SkoricDepartment of Electrical and Computer Engineering, McGill University, Montreal, QC H3A 2T5, Canada.
Shicheng XuDepartment of Electrical and Computer Engineering, McGill University, Montreal, QC H3A 2T5, Canada.
Philip J R RocheDepartment of Electrical and Computer Engineering, McGill University, Montreal, QC H3A 2T5, Canada.
Michel LortieMacDonald, Dettwiler and Associates Corporation, Ottawa, ON K2K 1Y5, Canada.
Stephane GagnonMacDonald, Dettwiler and Associates Corporation, Ottawa, ON K2K 1Y5, Canada.
David V PlantDepartment of Electrical and Computer Engineering, McGill University, Montreal, QC H3A 2T5, Canada.

Funding

Natural Sciences and Engineering Research Council of Canada CRDPJ 533817 - 18
6 · The paper itself

Abstract

Cardiography is an indispensable element of health care. However, the accessibility of at-home cardiac monitoring is limited by device complexity, accuracy, and cost. We have developed a real-time algorithm for heart rate monitoring and beat detection implemented in a custom-built, affordable system. These measurements were processed from seismocardiography (SCG) and gyrocardiography (GCG) signals recorded at the sternum, with concurrent electrocardiography (ECG) used as a reference. Our system demonstrated the feasibility of non-invasive electro-mechanical cardiac monitoring on supine, stationary subjects at a cost of $100, and with the SCG-GCG and ECG algorithms decoupled as standalone measurements. Testing was performed on 25 subjects in the supine position when relaxed, and when recovering from physical exercise, to record 23,984 cardiac cycles at heart rates in the range of 36-140 bpm. The correlation between the two measurements had r

Indexed as

AccelerometryAlgorithmsCardiovascular DiseasesElectrocardiographyHeartHeart RateHumansWearable Electronic Deviceselectrocardiographyelectromechanical cardiac activitygyrocardiographyheart rate monitoringseismocardiographyvibrational cardiographywearable sensors

Identifiers

PMID31398948
PMCPMC6719139

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked