Trial reportJournal of orthopaedic surgery and research2019
Percutaneous kyphoplasty assisted with/without mixed reality technology in treatment of OVCF with IVC: a prospective study.
Trial report in Journal of orthopaedic surgery and research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03959059 (Percutaneous Kyphoplasty Assisted With/Without Mixed Reality Technology in Treatment of OVCF With IVC), which is not on this map. Cited by 33 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Percutaneous Kyphoplasty Assisted With/Without Mixed Reality Technology in Treatment of OVCF With IVC: a Prospective Study
Who cites it
33 citing papers in PubMed, 3 syntheses or guidelines pooled it, 72 citations in OpenAlex.
- Prevalence and risk factors for residual back pain after percutaneous vertebral augmentation in osteoporotic vertebral compression fracture patients: a systematic review and meta-analysis.BMC musculoskeletal disorders · 2025Pooled it
- Re-evaluating vertebral height restoration assessment in osteoporotic compression fractures: a systematic review and meta-analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025Pooled it
- Augmented reality navigation in spine surgery: a systematic review.Acta neurochirurgica · 2021Pooled it
- Application of 3-dimensional printing guide template and pointed lotus-style regulator in percutaneous pedicle screw fixation for thoracolumbar fractures.Scientific reports · 2022Trial
- Mixed Reality for Localisation of Rib Fractures Before Surgical Stabilization: A Pilot Study of an Innovative Tool.Surgical innovation · 2026Article
- Augmented reality in non-instrumentation minimally invasive spine surgery: a narrative review and future perspectives.Journal of spine surgery (Hong Kong) · 2026Review
- Orthopedic surgery assisted by mixed reality technology: systematic review.Frontiers in surgery · 2026Review
- The digital evolution of surgical planning: a systematic review of immersive and interactive technologies.Frontiers in surgery · 2026Review
- Intraoperative use of mixed reality (MR) in humans across surgical disciplines: a major review.3D printing in medicine · 2025Article
- Bridging traditional gaps in medical training with mixed reality: insights from bronchoscopy education-a narrative review.Journal of thoracic disease · 2025Review
- Augmented Reality in Interventional Radiology: A Review of Systems, Ergonomics, Applications, and Outcomes.Journal of medical extended reality · 2025Review
- Review
- The role of navigation technology in anterior cruciate ligament reconstruction bone tunnel positioning.Journal of robotic surgery · 2025Review
- Satisfactory 2-year outcome of minimal invasive hybrid stabilization with double treated screws for unstable osteoporotic spinal fractures.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024Article
- Establishment of a risk prediction model for residual low back pain in thoracolumbar osteoporotic vertebral compression fractures after percutaneous kyphoplasty.Journal of orthopaedic surgery and research · 2024Article
- Database of segmentations and surface models of bones of the entire lower body created from cadaver CT scans.Scientific data · 2023Article
- Review
- Accuracy of Femoral Tunnel Localization With Mixed Reality Technology-Assisted Single-Bundle ACL Reconstruction.Orthopaedic journal of sports medicine · 2023Article
- Real-Time Navigation with Guide Template for Pedicle Screw Placement Using an Augmented Reality Head-Mounted Device: A Proof-of-Concept Study.Indian journal of orthopaedics · 2023Article
- Mixed Reality in Modern Surgical and Interventional Practice: Narrative Review of the Literature.JMIR serious games · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of this study was to assess the clinical outcome of percutaneous kyphoplasty (PKP) assisted with mixed reality (MR) technology in treatment of osteoporotic vertebral compression fracture (OVCF) with intravertebral vacuum cleft (IVC).
methodForty cases of OVCF with IVC undergoing PKP were randomized into a MR technology-assisted group (group A) and a traditional C-arm fluoroscopy group (group B). Both groups were performed PKP and evaluated by VAS scores, ODI scores, radiological evidence of vertebral body height, and kyphotic angle (KA) at pre-operation and post-operation. The volume of injected cement, fluoroscopy times, and operation time were recorded. And cases of non-PMMA-endplates-contact(NPEC) in radiological evidence was also recorded postoperatively. The clinical outcomes and complications were evaluated afterwards. All patients received 10 to 14 months follow-up, with an average of 12 months.
resultThis MR-assisted group (group A) acquired more about the amount of the polymethyl methacrylate (PMMA) injection and postoperative vertebral height and less about postoperative KA, fluoroscopy times, and operation time compared with the control group (group B) (P < 0.05). The VAS scores and ODI scores in both groups have improved, but more significantly in group A (P < 0.05). Also, more cases achieve both-endplates-touching of cement in group A (P < 0.05). And there are less of the loss of vertebral height, KA, and occurrence of re-collapse of the vertebra in group A during the follow-up (P < 0.05).
conclusionPKP assisted with MR technology can accurately orientate the position of IVC area, which can be augmented by the balloon leading to more satisfied vertebral height improvement, cement diffusion, and pain relief.
trial registrationClinicalTrials.gov Identifier: NCT03959059 . Registered 25 September 2016.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.