ArticleMagnetic resonance in medicine2020
Effects of different macromolecular models on reproducibility of FID-MRSI at 7T.
Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Rosette Spectroscopic Imaging for Whole-Brain Slab Metabolite Mapping at 7T: Acceleration Potential and Reproducibility.Human brain mapping · 2025Article
- Macromolecule Modelling for Improved Metabolite Quantification Using Short Echo Time BrainNMR in biomedicine · 2025Article
- High-quality lipid suppression and B0 shimming for human brainNeuroImage · 2024Article
- High-resolutionNMR in biomedicine · 2024Article
- Short symmetric and highly selective asymmetric first and second order gradient modulated offset independent adiabaticity (GOIA) pulses for applications in clinical MRS and MRSI.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2022Article
- In vivo macromolecule signals in rat brainMagnetic resonance in medicine · 2021Article
- Accelerated MR spectroscopic imaging-a review of current and emerging techniques.NMR in biomedicine · 2021Review
- Realistic head-shaped phantom with brain-mimicking metabolites for 7 T spectroscopy and spectroscopic imaging.NMR in biomedicine · 2021Article
- Intra-session and inter-subject variability of 3D-FID-MRSI using single-echo volumetric EPI navigators at 3T.Magnetic resonance in medicine · 2020Article
- High-resolution metabolic imaging of high-grade gliomas using 7T-CRT-FID-MRSI.NeuroImage. Clinical · 2020Article
- Effects of different macromolecular models on reproducibility of FID-MRSI at 7T.Magnetic resonance in medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
purposeA properly characterized macromolecular (MM) contribution is essential for accurate metabolite quantification in FID-MRSI. MM information can be included into the fitting model as a single component or parameterized and included over several individual MM resonances, which adds flexibility when pathologic changes are present but is prone to potential overfitting. This study investigates the effects of different MM models on MRSI reproducibility.
methodsClinically feasible, high-resolution FID-MRSI data were collected in ~5 min at 7 Tesla from 10 healthy volunteers and quantified via LCModel (version 6.3) with 3 basis sets, each with a different approach for how the MM signal was handled: averaged measured whole spectrum (full MM), 9 parameterized components (param MM) with soft constraints to avoid overparameterization, or without any MM information included in the fitting prior knowledge. The test-retest reproducibility of MRSI scans was assessed voxel-wise using metabolite coefficients of variation and intraclass correlation coefficients and compared between the basis sets. Correlations of concentration estimates were investigated for the param MM fitting model.
resultsThe full MM model provided the most reproducible quantification of total NAA, total Cho, myo-inositol, and glutamate + glutamine ratios to total Cr (coefficients of variations ≤ 8%, intraclass correlation coefficients ≥ 0.76). Using the param MM model resulted in slightly lower reproducibility (up to +3% higher coefficients of variations, up to -0.1 decreased intraclass correlation coefficients). The quantification of the parameterized macromolecules did not affect quantification of the overlapping metabolites.
conclusionClinically feasible FID-MRSI with an experimentally acquired MM spectrum included in prior knowledge provides highly reproducible quantification for the most common neurometabolites in healthy volunteers. Parameterization of the MM spectrum may be preferred as a compromise between quantification accuracy and reproducibility when the MM content is expected to be pathologically altered.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.