ArticleJournal of the American Society for Mass Spectrometry2019
Validation of Calibration Parameters for Trapped Ion Mobility Spectrometry.
Article in Journal of the American Society for Mass Spectrometry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Evaluation of TIMS-derived peptide mobility measurements: calibration strategy and MS1/MS2 discrepancies.Analytical and bioanalytical chemistry · 2026Article
- Coupling Capillary Electrophoresis With a Shifted Inlet Potential High-Resolution Ion Mobility Spectrometer.Electrophoresis · 2025Article
- Collision cross sections of large positive fullerene molecular ions and their use as ion mobility calibrants in trapped ion mobility mass spectrometry.Analytical and bioanalytical chemistry · 2024Article
- Atmospheric pressure field desorption-trapped ion mobility-mass spectrometry coupling.Analytical and bioanalytical chemistry · 2024Article
- Development of a Modular, Open-Source, Reduced-Pressure, Drift Tube Ion Mobility Spectrometer.Journal of the American Society for Mass Spectrometry · 2024Article
- timsTOF HT Improves Protein Identification and Quantitative Reproducibility for Deep Unbiased Plasma Protein Biomarker Discovery.Journal of proteome research · 2024Article
- A Comparison of the Performance of Modular Standalone Do-It-Yourself Ion Mobility Spectrometry Systems.Journal of the American Society for Mass Spectrometry · 2023Article
- Ion Mobility Mass Spectrometry (IM-MS) for Structural Biology: Insights Gained by Measuring Mass, Charge, and Collision Cross Section.Chemical reviews · 2023Review
- Tandem-trapped ion mobility spectrometry/mass spectrometry (The Analyst · 2022Review
- Insights and prospects for ion mobility-mass spectrometry in clinical chemistry.Expert review of proteomics · 2022Article
- Analysis of Peptide Stereochemistry in Single Cells by Capillary Electrophoresis-Trapped Ion Mobility Spectrometry Mass Spectrometry.Analytical chemistry · 2021Article
- Comment on Effective Temperature and Structural Rearrangement in Trapped Ion Mobility Spectrometry.Analytical chemistry · 2020Article
- Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations.Analytical chemistry · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Using contemporary theory for ion mobility spectrometry (IMS), gas-phase ion mobilities within a trapped ion mobility-mass spectrometer (TIMS) are not easily deduced using first principle equations due to non-linear pressure changes and consequently variations in E/N. It is for this reason that prior literature values have traditionally been used for TIMS calibration. Additionally, given that verified mobility standards currently do not exist and the that the exact conditions used to measure reported literature values may not always represent the environment within the TIMS, a direct approach to validating the behavior of the TIMS system is warranted. A calibration procedure is presented where an ambient pressure, ambient temperature, two-gate, printed circuit board drift-tube IMS (PCBIMS) is coupled to the front of a TIMS allowing reduced mobilities to be directly measured on the same instrument as the TIMS. These measured mobilities were used to evaluate the TIMS calibration procedure which correlates reduced mobility and TIMS elution voltages with literature values. When using the measured PCBIMS-reduced mobilities of tetraalkyl ammonium salts and tune mix for TIMS calibration of the alkyltrimethyl ammonium salts, the percent error is less than 1% as compared with using the reported literature K